PROFESSIONAL AUTOMATIC SYSTEM FOR GATES AND GARAGE DOORS
Programming functions
DIP1
ON
DIP1
OFF
DIP2
ON
DIP2
OFF
DIP3
ON
DIP9
ON
DIP9
OFF
DIP10
ON
Trimmer adjustment
There are 4 trimmers (V1-V2-V3-V4) on the F4PLUS control unit to adjust the following:
V1
FORCE
V2
RUN TIME
PHASE SHIFT
V3
TIME
V4
PAUSE TIME
Cutouts
DIP4 in ON
DIP5 in ON
DIP6 in ON
DIP7 in ON
DIP8 in ON
WARNING!
In the event of a system with only one motor and using the limit switches, the dip switches 4, 5, 6 and 7 must all be set to OFF, while
if using only one type of limit switch, e.g. Fa1 and/or Fa2, enable (OFF position) only the corresponding dip switch.
When the photocell is intercepted, both during opening and closing, the gate motion is locked until
the photocell is freed. Subsequently, there is always an opening phase.
The photocell stops and immediately inverts the motion of the gate during the closing phase, while during
opening it is uninfluential.
Enables the CONDOMINIUM function, i.e. one STA RT command opens the gate, and no other STA RT commands are
accepted during opening. During PAUSE, one STA RT command reloads the pause time. During closing, one STA RT
command reopens the gate. Reclosing occurs only in automatic mode after the pause time, also when V4 is on minimum.
Enables the STEP-BY-STEP functions (one STA RT command OPENS, a second command STOPS, a third command
CLOSES the gate) or STEP-BY-STEP with AUTOMATIC RECLOSING depending on how trimmer V4 is positioned:
• If turned completely anticlockwise = STEP-BY-STEP
• If turned clockwise = STEP-BY-STEP with RECLOSING i.e. after the pause time it recloses automatically. To close with
•
the remote control during the pause, two start commands must be given (the first command sets the gate to STOP).
Enables the WATER HAMMER function - exercises a brief thrust during closing before opening, facilitating re l e a s e
of the electric lock (if the limit switches are used, this function is disabled)
The outputs 7-8 of the terminal board are used to control a FLASHLIGHT equipped with its own flashing
circuit (code 70106)
The outputs 7-8 of the terminal board become outputs for the COURTESY LIGHT and remain active for
3 minutes after the run time (max. 100W).
a flashlight without flashing circuit.(code 70107)
Enables PEDESTRIAN GATE OPENING with the 2nd key of the remote control. (F4PLUS/RR only).
Turned clockwise it adjusts the motor torque from 40% to 98%.
For the first 3 seconds pickup occurs.
Turned clockwise, it adjusts the RUN TIME from 2 to 100 seconds.
Tu rned clockwise, it adjusts the delay time between the start of the closing mouvement of motor 2 and
the start of the closing of motor 1 (from 0 to 20 seconds). The phase shift during opening is fixed at
2 seconds. With V3 set to minimum the delays are cancelled both during opening and closing
(double sliding gate version) and the WATER HAMMER function is disabled.
Turned clockwise it adjusts the PAUSE TIME from 2 to 100 seconds. Adjusted to minimum, it
disables the pause time = STEP-BY-STEP function.
Cuts out limit switch input - opens motor 1
Cuts out limit switch input - closes motor 1
Cuts out limit switch input - opens motor 2
Cuts out limit switch input - closes motor 2
Cuts out photocell input
In this mode the terminals 28-29 can be used to connect
7
English