GiBiDi F4 Plus Manual Tecnico página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
English
Final checks and testing
Before powering the control unit, check the following:
1) Check that the dip switches and trimmers have been set properly according to requirements.
2) Check the electrical connections; Improper connection may cause damage to the control unit and the operator.
Power the devices
3) Check that the red LEDs of the safety devices are on and the yellow LEDs off
4) Check that when engaging any limit switches used the corresponding LEDs come on.
5) Check that when passing through the beam of the photocells the corresponding LED goes off.
6) Check that the motors are locked and ready for operation. Remove any obstacles from the operating range of the gate, then give the
6)
START command. Upon the first command, the control unit starts an opening phase; check that the motor rotation direction is correct.
6)
If not, invert the wires of terminals 1-3 and/or 4-6.
7) Fine adjust the trimmers.
Radio Module
The control unit in the /R version is equipped with a DECODING circuit (both DIP SWITCH and ROLLING-CODE (max. 200 codes) and
functions by plugging only the radio, in the desired frequency, into the special connector (see codes AJ0018-AJ0019-AJ0020).
The /RR version comes complete with receiver with 433.92 MHz operating frequency.
Code learning:
When powering the control unit for the first time, check that the red code-learning LED is on, indicating that the receiver is ready to learn
a remote control (whether DIP SWITCH or Rolling-Code with automatic recognition of the type).
One of the keys of a transmitter can now be pressed (1-2-3 or 4).
When the code has been learned, a command is given to the control unit.
Without pressing the CH1 key again, further remote controls of the same family can be learned, one after the other.
After learning the last remote control, wait for the LED to go off (about 6 seconds) indicating that the system has exited TX learning and is
ready to operate normally.
WARNING: After learning the first code, the system will accept only that family of codes (if the first is Rolling all the others must be Rolling).
If learning is for DIP SWITCH transmitters, only one remote control needs to be learned.
MEMORY RESET: If a mistake is made or all the codes need to be deleted, press the CH1 key (the red LED comes on) and hold it pressed
down until the LED goes off again. When the key is released, the LED flashes (indicating that the memory is empty) and then comes back
on, indicating that the system is ready to learn a new remote control (whether DIP SWITCH or Rolling-Code).
When learning a remote control key, which is positioned on channel 1 (the one which controls full opening of the gate), the system
automatically learns the 2nd key of the remote control which, if enabled with DIP10 (ON), controls the PEDESTRIAN GATE START.
Remote control learning without accessing the control unit:
After letting the system learn a remote control in manual mode (by pressing the key S1), self-learning of other remote controls of the same
family can be enabled by simultaneously pressing (for 2 seconds) the keys 1 and 2 of the transmitter already learned. Subsequently, when
pressing the key of a new remote control it is self-learned.
Learning has been successful when it moves the gate.
Default settings
DIP SWITCHES 1, 2, 3, 9, 10 OFF; DIP SWITCHES 4, 5, 6, 7, 8 ON
Trimmer V1 adjusted to maximum,
Trimmers V2, V3 and V4 adjusted to half their travel.
AUTOMATISMI PROFESSIONALI PER CANCELLI E GARAGE
8

Publicidad

Tabla de contenido
loading

Tabla de contenido