EN
+
You will find the illustrations referred to above in the pages 2 – 4 of these
instructions for use.
Scope of delivery
Tank [1] with pump [2], plug-in coupling [3], hose [5], Instructions for Use [6]. (Fig. 1)
Technical data
Max. filling amount
Total contents
Max. pressure
Max. operating temperature
Weight when empty
Max. total weight
Material of tank
Technical residual quantity
Table 1
Assembly
1. Push the hose [5] into the opening [7] and secure it with the cap nut. (Fig. 2)
Checks
Visual inspection: Are tank [1], pump [2] and hose [5] undamaged? (Fig. 1)
+
Pay special attention to the connection between the tank and hose and to the condi-
tion of the pump thread.
No leaks: Pump up the empty device to 2 bar (29 psi) (Fig. 9).
► The pressure must not decrease more than 0.5 bar (7.35 psi) within 30 minutes.
Function: Pull up the piston pressure gauge [8] (Fig. 3)
► The pressure must dissipate.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
5 l (1.3 gal)
6.9 l (1.8 gal)
3 bar (43.5 psi)
30 °C (86 °F)
1.5 kg (3.3 lb)
6,5 kg
Polyethylene
< 0.04 l (1.35 oz)
13
ENGLISH