Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.
4.8.1
Led B - Thickness.
In Standard program mode, Pulsed arc program mode, Job mode and Manual mode, display O
shows the recommended thickness based on the current and wire speed set by the selected program.
In Parameter Selection Internal mode, display O shows the recommended thickness based on the set
current and wire speed. The value may be changed using the knob N. This change affects the value of the
set voltage, which may be seen on display P with led J lit.
4.8.2
Led C - Wire speed.
In Standard program mode, Pulsed arc program mode, Job mode and Manual mode, display O
shows the welding wire speed set in the selected program.
In Parameter Selection Internal mode, display O shows the welding wire speed set in the selected
program. The value may be changed using the knob N. This change affects the value of the set voltage,
which may be seen on display P with led J lit.
4.8.3
Led D - Current.
In Standard program mode, Pulsed arc program mode and Job mode, display O shows the welding
current preset in the selected program or, if in combination with led F lit, the actual welding voltage is
measured.
In Manual mode, display O reads 0 (zero). Only after a welding in combination with led F lit does it
indicate the actual welding current measured.
In Parameter Selection Internal mode, display O shows the preset welding current of the selected
program. The value may be changed using the knob N. This change affects the value of the set voltage,
which may be seen on display P with led J lit.
4.9

Knob N.

Operative in Parameter Selection Internal mode and within the "Service Functions" (par. 6) and the
"Second Functions" menu (par. 7).
In Parameter Selection Internal mode, it adjusts the values indicated by the leds B, C and D (par. 4.8).
The value is shown on display O.
In "Service Functions" it selects the abbreviation rcL and dEL for the functions "recall" rcL and "delete"
dEL. The abbreviations are visible on display O.
Based on the function called up, the "Second Functions" menu displays the abbreviations H2O, SP (tSP,
tin), HSA (SC, tSC, Slo), CrA (tCr, Slo, CrC), dP (FdP, ddP, tdP, Adp), Ito, rob, GAS, FAc. The
abbreviations are visible on display O.
4.10
I key.
Always operative.
Each time this key is pressed, it calls up the measure you wish to show on display P.
The selected measure is indicated by the lighting of the corresponding led.
4.10.1
Led J - Voltage.
In Standard program mode, Pulsed arc program mode and Job mode, display P shows the welding
voltage preset in the selected program or, if in combination with led F lit, the actual welding voltage is
measured.
In Standard program mode and Pulsed arc program mode, if the knob Q is turned, display P
temporarily displays (5 seconds) the "Arc Length" correction indicated by led K lit.
In Manual mode, display P shows the preset welding voltage or, if in combination with led F lit, the
actual welding voltage measured.
In Parameter Selection Internal mode, display P shows the preset welding voltage of the selected
program. The value may be changed using the knob Q.
4.10.2
Led K - Arc length.
Indicates that an "Arc Length" correction is in progress.
Display P shows the value (-9.9 to +9.9, default =0).
A negative number indicates a reduction in the arc length, a positive number its extension.
In Standard program mode and Pulsed arc program mode, the value of the correction may be changed
using the "Arc Length correction" adjustment from the Robot Terminal.
3.300.162-D
29
GB
04/03/2016

Publicidad

Tabla de contenido
loading

Tabla de contenido