To exit the "program" function without deleting any programs, briefly press the AP key; the led M shuts
off and the Control Panel returns to normal operations.
6.5

AP key - Deleting working programs (Job).

A working program (Job) cannot be changed from the Robot Terminal but only via the Control Panel.
From the Robot Terminal, select the Parameter Selection Internal mode to make the Control Panel
operative.
Press the AP key to activate the "program" function (led M lit). Display O reads Sto and display P
flashes the first free "Job number".
Use knob Q to choose the "Job number" that you intend to delete (the message on display P becomes
steady, to indicate the number of an existing Job).
Use knob N to choose the abbreviation dEL, on display O.
Hold down the AP key for longer than 3 s; an acoustic signal (beep) signals deletion of the Job; the
message on display P begins to flash (free "Job number").
To exit the "program" function without deleting any programs, briefly press the AP key; the led M shuts
off and the Control Panel returns to normal operations.
6.6

AP key - Changing the working programs (Job) (recall function).

A working program (Job) cannot be changed from the Robot Terminal but just from the Control Panel.
From the Robot Terminal, select the Parameter Selection Internal mode to make the Control Panel
operative.
Press the AP key to activate the "program" function (led M lit). Display O reads Sto and display P
flashes the first free "Job number".
Use knob Q to choose the "Job number" that you intend to change (the message on display P becomes
steady, to indicate the number of an existing Job).
Use knob N to choose the abbreviation rcL, on display O.
Hold down the AP key for longer than 3 s; an acoustic signal (beep) signals acceptance of the Job. When
the job has been accepted, the Control Panel exits the "program" function (led M off) and returns to
normal operations.
From the Control Panel it is now possible to change the parameters of the selected Job.
To exit the "program" function without calling up any Job, briefly press the AP key; the led M shuts off
and the Control Panel returns to normal operations.
Once the parameters have been changed and the welding done, the new Job may be saved using the
saving procedure in par. 6.4.