FIG. 11
Pilot
Adjustment
Follow the instructions included with the thermostat. Locate the thermostat approximately five feet above the floor. Always
mount the thermostat on an inside wall where it won't be affected by heat or cold sources such as direct sunlight, televisions,
fireplaces, hidden hot or cold water pipe, drafts, etc. The thermostat must never be installed in an adjoining room where a door
can be closed between the thermostat and floor furnace. This floor furnace is equipped with a self-generating control system.
Never connect to a 24-volt transformer or to the household electric system. Do not use more thermostat wire than is included
with the floor furnace.
Step 1. Connect black limit switch wire to black thermostat wire using wire nut. (Nut not furnished).
Step 2. Connect white thermostat wire to terminal on gas valve marked "TH TP".
Step 3. Connect white limit switch wire to terminal on gas valve marked "TH".
Step 4. Connect the thermostat wires to the thermostat following the instructions provided by the thermostat manufacturer.
FIG. 12
Terminal Block On Gas Valve
CHECKING THE GAS PIPING - Continued
When you have determined that there are no leaks in the gas piping
system you may purge the system of air. Disconnect the pilot supply
Limit Switch
tubing from the right side of the valve. See Figure 12.
Wires
Tum the knob on the gas valve to the pilot position. Press the knob
down and hold until you smell gas at the pilot supply opening. Release
the knob and tum it to the off position. Reconnect the pilot supply
tubing and check for leaks with soap and water or liquid detergent.
Pilot Supply
Tubing
Pressure Tap
THERMOSTAT INSTALLATION
WIRE AS INDICATED: (See Figure 12)
Thermostat
Wire Nut
Page 11
WARNING: When purging gas piping, the area around the floor
furnace must be well ventilated to allow any gas to dissipate. Liquid
Petroleum (Propane) Gas is heavier than air and may puddle in
low places under the floor. Check thoroughly to determine that no
gas is present before lighting the floor furnace. Failure to do so
could result in property damage, bodily injury or death.
Limit Switch Wires
Powerpile
Generator
Thermostat
Back to Index
Limit
Switches
Red
Powerpile
Generator
TH
TP
TH
TP
TH
TP
TH
TP
Terminal Block
1017826-A