1. WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
personal injury or loss of life. Installation and service must
be performed by a qualified installer, service agency or the
gas supplier keep burner and control compartment clean.
See installation and operating instructions accompanying
appliance. Due to high surface temperatures keep children,
clothing and furniture away.
2. Follow all applicable codes and ordinances. If there are none,
follow the installation standards, latest edition of NFPA54/
ANSI.Z223.1. A copy may be obtained from the National
Fire Protection Association, 1 Batterymarch Park; Quincy,
MA, 02269.
3. DO NOT install this floor furnace in a recreational vehicle,
trailer or mobile home.
4. DO NOT operate this floor furnace unless it is connected
to aproperly installed and maintained vent system. Do not
exhaust flue gases under the floor for any reason.
5. Be sure this floor furnace is equipped for the type gas you
intend to use.
6. Locate the thermostat in a room or space that cannot be
separated by adoor or other means from the room or space
in which the floor furnace grill is installed.
!
WARNING: CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each appliance connected to the venting system being placed into
operation could result in carbon monoxide poisoning or death.
The following steps shall be followed for each appliance connected to the venting system being placed into operation, while
all other appliances connected to the venting system are not in operation:
1) Seal any unused openings in the venting system.
2) Inspect the venting system for proper size and horizontal
pitch, as required in the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 or the Natural Gas and Propane Installation
Code, CSA B149.1 and these instructions. Determine that
there is no blockage or restriction, leakage, corrosion and
other deficiencies which could cause an unsafe condition.
3) As far as practical, close all building doors and windows
and all doors between the space in which the appliance(s)
connected to the venting system are located and other
spaces of the building.
4) Close fireplace dampers.
5) Turn on clothes dryers and any appliance not connected
to the venting system. Turn on any exhaust fans, such as
range hoods and bathroom exhausts, so they are operating
at maximum speed. Do not operate a summer exhaust fan.
1017826-A

SAFETY

7. Never use a match, candle, flame or other source of ignition
to check for gas leaks. Use only soapy water or liquid
detergent.
8. Adequate air for combustion and venting must be provided.
9. If it is suspected that rising water or seepage may enter the
floor furnace, turn off the gas immediately. Do not use this
floor furnace if any part has been under water. Immediately
call a qualified service technician to inspect the floor furnace
and to replace any part of the control system and any gas
control which has been under water.
10. Have your floor furnace and vent system inspected before
using and at least annually by a qualified service technician.
11. The grill becomes hot when the floor furnace is in operation.
Children must be closely supervised when in the presence
of any heating appliance. Contact with bare skin may result
in severe burns. Keep children off the grill.
12. Before cleaning or servicing the floor furnace, turn off the
gas and allow it to cool. This will prevent burns.
13. Always leave the grill in place except when cleaning or
servicing the floor furnace.
14. Never operate the floor furnace without the sight glass
assembly in place, or with the glass broken or missing.

VENTING

6) Follow the lighting instructions. Place the appliance being
inspected into operation. Adjust the thermostat so appliance
is operating continuously.
7) Test for spillage from draft hood equipped appliances at
the draft hood relief opening after 5 minutes of main burner
operation. Use the flame of a match or candle.
8) If improper venting is observed during any of the above
tests, the venting system must be corrected in accordance
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54
and/or Natural Gas and Propane Installation Code, CSA
B149.1.
9) After it has been determined that each appliance
connected to the venting system properly vents when tested
as outlined above, return doors, windows, exhaust fans,
fireplace dampers and any other gas-fired burning appliance
to their previous conditions of use.