1
DESCRIPTION
SANICOMPACT
®
Comfort/SANICERAMIC 4
is a wall hung WC pan fitted with a pump
macerator.
The SANICOMPACT
®
Comfort/
®
SANICERAMIC 4
can only be installed with
the special support brackets supplied.
SANICOMPACT
®
Comfort/SANICERAMIC 4
is for use in a domestic environment.
Installed and used correctly, SANICOMPACT
®
Comfort/SANICERAMIC 4
will give reliable
and consistent service.
Please note the following warning signs:
"
" Possible danger to personnel,
"
" Warning of possible electrical hazards,
"WARNING" This is a general warning that
failure to follow instructions could result in
poor functioning of the unit.
PRINCIPLES OF OPERATION
SANICOMPACT
®
Comfort/SANICERAMIC 4
is controlled by an electronic timer.
It macerates and pumps away waste:
The unit is operated by pressing one of the
two options of the grey pushbutton built into
the bowl (light grey: short flush, dark grey: full
flush).
2
LIST OF ACCESSORIES SUPPLIED
3
DIMENSIONS
4

TECHNICAL DATA

Applications
WC discharge
Type
Maximum Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption 2,5 A
Medium water temperature
Electric Class
Degree of protection
Net Weight (with frame)
WARNING:
Only installations conforming to
the above specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL
PUMPING COMBINATIONS
7
INSTALLATION
PREPARATIONS
NB:
before installing your SANICOMPACT
Comfort/SANICERAMIC 4
®
, make sure that
the wall which is to bear the load is strong
enough to support the appliance. (Max shear
force per fixing: 120kg).
7a
FIXING THE BOWL ONTO THE
SUPPORTING UNIT
1
- Secure the M12 rods
fixing holes so the following length
protrudes:
L = 45 mm + X (X = thickness of any
covering panel, plasterboard or tiling).
®
2
- Position the plastic inserts
holes of the bowl.
NB:
make sure the side opening in the
insert is in line with the side opening in
the bowl
®
®
7b
ADJUSTING THE HEIGHT OF THE UNIT
1
- Attach the feet
and screw into the frame.
2 -
Offer the support unit up to the wall.
3
- Adjust the height of the bowl above
the floor: for a seat height of 430mm
(standard height), adjust the rods
to protrude by 65mm.
Check that the unit is horizontal.
®
7c
FIXING THE UNIT TO THE WALL
1 -
Offer the unit up to the wall.
2 -
Check that the unit fits flush to the wall.
3
- Mark the unit fixing points (2 holes in the
upper part of the unit and 2 holes in the
lower part).
4
-
NB:
if your wall is not perfectly vertical,
use the four holes provided on the unit to
make good any gap between it and the
wall by adding washers.
These gaps are filled by adding flat washers –
not supplied – between the wall and the unit.
5 -
Choose wall fixings suitable for the wall
material (use 8mm x 120 mm or larger –
not supplied).
6
- Drill holes in the wall using a suitable
CR15 DF
size of bit – not supplied – for the
3 m
chosen fixing.
220-240 V
7
- Fix the unit to the wall.
50 Hz
550 W
8
-
NB:
The distance between the wall and the
35°C
front of the covering panel must not
I
exceed 100mm.
IP44
The covering panel must always be right up
32 Kg
against the unit.
7d
WATER SUPPLY
1 -
Run the water supply with copper pipe
in 15 mm, fitted with a 22 mm male iron
to connect to the SANICOMPACT
Comfort/SANICERAMIC 4
2 -
The water supply pipe must be fitted in
the upper part of the frame.
3 -
WARNING:
isolation valve when fitting the pan.
4 -
For correct rinsing of the bowl, the water
®
pressure entering the pan must be
minimum 1,7 bar.
in the frame's
A
in the
D
to the M10 rods
B
A
A
®
®
.
It is essential to install an
8
7e
DISCHARGE CONNECTION
1 -
The discharge pipe should be either
copper or UPVC solvent weld pipe with
32 mm diameter.
2 -
Put the end of the pipe through the
upper part of the frame.
If the discharge pipework runs to a level
3 -
considerably lower than SANICOMPACT
Comfort/SANICERAMIC 4
resultant syphoning effect can suck out the
water seal in the unit. Fitting an air admit-
tance valve (BBA approved) at the high
point of the pipe run will overcome this pro-
blem.
7f ELECTRIC POWER SUPPLY
7f
The electrical installation work must be
carried out by a qualified person.
The electrical installation work for the
equipment, in a bathroom, must be carried
out in accordance with the standards in force
in the country (NF C 15-100 in France).
The electric power supply as wired
beforehand by the installer must be class 1,
using 3 X 0.75 sq. mm wiring.
1 – Connect the electric power supply to a
triple screw connector (not supplied) in
an
IP55 junction box (Sarel 01650 or
similar) installed beforehand, complying
with the following colours:
Brown = phase
Blue = neutral
Green/Yellow = earth.
2 – This connection must be used solely to
power the equipment, and it must be
protected by a high sensitivity 30mA
differential circuit breaker, set at 16 A.
3 -
ATTENTION:
the electrical junction box
must remain accessible after installation
of the toilet.
8
MOUNTING THE PAN AND
CUTTING OUT THE FASCIA
PANEL
1 -
Offer up the fascia panel (not provided) to
the support frame which has been fixed to
the wall.
2 -
Locate the panel exactly to the support
frame.
3
- Drill 2 holes (25mm) through the fascia
panel to correspond with the threaded rods
on which the pan will hang.
4
- Offer up the template
to the support wall
C
fascia, positioning the holes for the WC
support rods accordingly.
5 -
Trace the inner shape of the template onto
the fascia.
6
- Remove the template
and cut out the
C
fascia as traced.
7
- Make any finishes to the support wall and
fix on the fascia panel.
8 -
Note:
If you are tiling the wall, the tiles will
have to be cut out in the same way as the
fascia panel.
®
®
unit, the

Publicidad

loading

Este manual también es adecuado para:

Saniceramic 4