6. Wire Connecting
Make sure that the power is OFF before making any electrical connections.
Remove the cover, perform the wiring (See Fig.8 and wiring notes for control board) and replace the cover again.
VR1
SW1
U2
MOT
CAP
J6
Capacitor
MOT1
J4
MOTOR
MOT2
MOT
COM
Q3
Caution light
Protect Earth
POWER
J3
Wiring notes of control boar
a.
Power Input (terminal J3): PE (Earth),L (Live),N (Neutral).
SL600AC: AC220V
SL600ACU:AC110V
b. Caution light: connect caution light wire to L and N of LAMP(terminal J4)
SL600AC: AC220V
SL600ACU: AC110V
c.
Output power supply: 12VDC(7 of J5), COM (9 of J5), I.R. (8 of J5 is N.C Infrared)
If the infrared beam is interrupted during closing, the gate will reverse and open immediately.
The product is not factory equipped with an infrared device; the infrared output signal must be N.C.
From four-terminal
to the receiver
Terminal J5
9
COM
8
OUT
7
Control board
RX Receiver connecting
d. The operator could be managed with a three-button switch / single-button switch
To be work with o single-button (terminal J2 : 5 and the other to the '4(COM)'.
For three-button switch installation, use the terminals for multi-channel mode. Connect open wire of
external button switch to '1 (OPEN)' of terminal J2, connect close wire of switch to '2 (CLOSE)', connect stop
wire of switch to '3(STOP)', connect common wire of switch to '4(COM)'.
VR2
VR3
VR4
ON
OFF
U1
J1
S1
C22
U3
C20
OC2
F3
OC1
C19
F1
VDR1
F2
T2
Form two-terminal to the emitter
12--24V AC/ DC
JUMP
NC OR NO
https://appceso.com
Learn button
Open limit
Limit
COM
swtich
Close limit
Loop detector
GND/COM
Infared sensor
+12VDC
Pedestrian switch
O/S/C switch
COM
Extral button
switch
power supply
NC
NO
TX Emitter connecting
Fig.8
Fig.9 infrared Schematic diagram