8.3 - ACTIVATION INPUT
The control unit has an activation input (START) for the connection
of a N.O. button.
Connect the cables of the device that controls the START
between terminals L3 (START) and L6 (COM)
C
The operating logic of the START button and of the START
remote control (channel 1 on the receiver) depends on the
settings performed on the following parameters:
St.AP
: Start command during opening phase
PAUS
(default =
St.Ch
: Start command during closing phase
StoP
(default =
St.PA
: Start command during Pause
Chiu
(default =
the gate closes)
L11
L10
L9
L8
L7
L6
L5
The START function can also be enabled by means of a remote
control saved on channel 1 of the MR receiver.
8.4 - CONNECTING PHOTOCELLS
PD22 control unit supplies a 24Vdc power supply to photocells.
Photocell power terminals are protected by an electronic fuse that
stops current in case of overload.
C
The input is disabled by default; to enable it, change the
Foto
settings of the
parameter
•
Connect power supply cables of photocells transmitter
between terminals L8 (COM) and L9 (+) of the control unit.
•
Connect power supply cables of photocells receiver between
terminals L7 (+) and L8 (COM) of the control unit.
•
Connect N.C. receiver output between terminals L6 (COM)
and L4 (PHOTO) of the control unit. Use outputs having
normally closed contact.
TX
RX
L11
L10
L9
L8
L7
L6
L5
the gate goes in standby)
the gate stops and the cycle ends)
L4
L3
L2
L1
L4
L3
L2
L1
8.5 - STOP / SAFETY EDGE
The control unit is equipped with a configurable safety input that
can be used to connect a STOP button to a safety edge.
C
The input is disabled by default; to enable it as STOP or
EDGE, you need to change the settings of the
SiC
parameter
STOP button
To connect a STOP button, you need to set the parameter
SiC = StoP
Connect the cables of the STOP button (N.C.) between terminals
L5 (STOP) and L6 (COM).
Opening the button will cause the motor to stop and will cancel
the automatic closing command (if enabled).
L11
L10
L9
L8
L7
L6
The STOP function can also be enabled by means of a remote
control saved on channel 3 of the MR receiver.
Safety edge
To connect a safety edge, you need to set the parameter
SiC = EdGE
Connect the cables of the safety edge between terminals
L5 (EDGE) and L6 (COM).
L11
L10
L9
L8
L7
L6
The intervention of the edge during the closing phase will cause
the gate to open completely and will cancel the automatic closing
command (if enabled).
This input can control either the classic edge with N.C. contact,
or the conductive rubber ones with nominal resistance 8,2 kohm.
m
WARNING:
•
When using more edges with N.C. contact, the inputs have to
be series connected.
•
If using more conductive rubbers, the outputs have to be
cascade connected and only the last one has to be terminated
on the nominal resistance.
- 32 -
L5
L4
L3
L2
L1
L5
L4
L3
L2
L1