12 - PROGRAMMING THE OPERATING
PARAMETERS
The programming menu -PrG contains a list of configurable
items: once you enter this menu, a symbol appears on the display
indicating the currently selected item. Press the
h
next item; press the
key to return to the previous item.
i
By pressing
, you will pass to the next item; by pressing
will return to the previous item.
Press OK to view the current value of the selected parameter and
h
i
use the keys
and
to change its value, if you want; to confirm
the new value, press once again OK.
To access the menu follow these instructions:
1. Press and hold down the OK key until the
the display
2. Release the OK key: the display will show
FinE
The last menu item (
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu
item if you do not want to lose your configuration.
PARAMETER
VALUE
EnSA
no
Si
Ch.AU
no
0.5" - 4h00
PA.C.
no
bEEP
FLSh
b.F.
i
key to go to the
h
, you
-PrG
appears on
En.SA
DESCRIPTION
Energy saving function
This function is useful for reducing the energy consumption of the
automation device while in stand-by mode.
ATTENTION: If there is a B-PACK backup battery installed, this
parameter should be set to
ECO-LOGIC device, this parameter should be set to
If the function is enabled, the control unit will enter ENERGY
SAVING mode under the following conditions:
• 30 seconds after completion of an operational cycle
• 30 seconds after an opening (if automatic closure is not enabled)
• 30 seconds after exiting the programming menu
In ENERGY SAVING mode, power to the accessories, display,
flashing lights and closure electromagnets is deactivated.
ENERGY SAVING mode is exited:
• If an operational cycle is activated
• If you press OK
Function deactivated
Function activated
Partial opening
Function deactivated
The gate closes automatically after the set time.
NOTE: 20 seconds before the automatic closure of the gate, the
built-in light flashes and the buzzer emits BEEPS to warn the user
of the upcoming closure.
Automatic closing pre-alarm
20 seconds before the automatic closing of the door (if activated) the
control unit sends alerts to warn the operator that the door is closing
Function deactivated
Sound pre-alarm: the internal buzzer emits BEEPS
Visual pre-alarm: the integrated light flashes
Sound + visual pre-alarm
m
WARNING: in case no operation is carried out for
more than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
i
By holding down the
FinE
scroll fast, until item
reach either the top or bottom of the list.
-PrG
no
. If ATRIS is powered by the
Si
- 39 -
h
or
keys, configuration menu items will
is viewed. In this way, you can quickly
FinE
En.SA
Ch.AU
DEFAULT
no
no
b.F.
MEMO