PARAMETER VALUE
vEL.A
hi
Lo
vEL.C
hi
Lo
P.APP
0 - 100
St.AP
PAUS
no
ChiU
St.Ch
Stop
APEr
St.PA
ChiU
no
PAUS
SEn.A
no
1.0A - 12.0A
SEn.C
no
1.0A - 12.0A
Foto
no
Si
DESCRIPTION
Opening speed (only ATRIS1000-F)
WARNING: It is recommended to perform the force self-learning
SEn
(
menu) each time the value of this parameter is modified.
High speed (20 cm/s)
Low speed (12 cm/s)
Closing speed (only ATRIS1000-F)
WARNING: It is recommended to perform the force self-learning
SEn
(
menu) each time the value of this parameter is modified.
High speed (20 cm/s)
Low speed (12 cm/s)
Partial opening percentage
Percentage of travel the door performs when a partial opening command is
received.
NOTE: Partial opening can only be controlled by radio via channel 2 of the
receiver.
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
The door stops and goes to pause
The START command is ignored
The door immediately starts closing
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
The door stops and the cycle ends
The door opens again
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a Start
command when the door is open during its pause phase
The door recloses
The START command is ignored
The pause time is reset (if the parameter
given during the pause enables the gate closing phase)
Sensitivity of the obstacles sensor during the opening phase
Function deactivated
When the current absorbed by the motor exceeds the set value, the control
unit detects an alarm, the gate stops and the display shows the message
SEnS
for several seconds
Sensitivity of the obstacles sensor during the closing phase
Function deactivated
When the current absorbed by the motor exceeds the set value, the control
unit detects an alarm, reopens the gate completely and the display shows
SEnS
the message
for several seconds
Photocell input
Input disabled
Input enabled during closing phase. The intervention of the photocell
causes the gate to open completely.
Ch.AU
no
=
, a START command
- 40 -
DEFAULT
MEMO
hi
Lo
20
PAUS
StoP
ChiU
no
no
no