Programming And Confi Guration; Programming (Or Modifying) Cycle Data; Programming Of Starting Setpoint (If Not Confi Gured, See Par. 6.1.2) - Pixsys ATR 902 Manual Instalador

Ocultar thumbs Ver también para ATR 902:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Programming and confi guration

7
There are two programming levels:
1. Cycles programming (for operator/user), to enter time/setpoint values for
each step of cycle.
2. Confi guration (for manufacturer/installer of plant), to enter main
parameters (sensor type, output type, intervention type alarm/auxiliary
ext.).

Programming (or modifying) cycle data

7.1
• With or without starting setpoint
• With or without timed auxiliary outputs
When controller is in
Press
1
Red display visualizes
CYCLE
Programming of starting setpoint (if not
7.1.1
confi gured, see par. 6.1.2)
The selection of an initial setpoint (a specifi c starting temperature of the cycle)
grants the correct gradient if the kiln is still heat from a previous process.
Press
Red display visualizes
Green display shows the
2
STEP
"starting setpoint".
Otherwise pass to point 4.
Increases, decreases value on
3
green display.
1
This section includes all available options for the cycle programming. Some of these steps can be
omitted if not all the controller functions are used. We recommend the manufacturer to indicate
into the kiln documentation the correct sequence of operations.
16
ATR902 - User manual

follow the points below.
Display

Display

1
At each pression selects the next

cycle (
  
for cycle 15).
*.
At any time press
programming.
Select starting setpoint (starting
temperature).
Do
for cycle no.2 up to
Do
to exit
START
STOP

Publicidad

Tabla de contenido
loading

Tabla de contenido