Programming Of The Step (Segment); Programming Of The Alarm/Auxiliary (If Confi Gured); End Programming - Pixsys ATR 902 Manual Instalador

Ocultar thumbs Ver también para ATR 902:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Programming of the step (segment)

7.1.2
Press
Red display visualizes
4
STEP
Green display shows step time.
Increases, decreases value on
green display.
5
N.B.:Each cycle is composed of
max. 18 programmable steps,
after those it skips automatically
to point 10.
Red display visualizes
Green display shows the step
6
setpoint (temperature that has
STEP
to be reached within given
time).

Programming of the alarm/auxiliary (if confi gured)

7.1.3
Press
Red display visualizes
7
Green display shows
STEP

8
9
Back to point 4.
STEP

End programming

7.1.4
Press
The controller backs to STOP
10
mode, saving the cycle. Red
STEP
display visualizes
Display
Display

.
Display


.
Enter the step duration in
hours:minutes.
N.B.: Set

or
steps are used) and skip to point
10.

.
With
setpoint (temperature reached
at step end).

 
If
or
auxiliary time (
point 10.
Select auxiliary output status
during the step:
output and
output.
.
Do

for endless time
for cycle end (if not all
or
select the
Do
is not programmed as



for not active
Do
ATR902 - User manual
) skip to
for active
17