1.2 Placement
The appliance has been designed to be installed in closed premises;
it cannot be used outdoors and must not be exposed to weathering.
The designated installation location must
have a rigid, flat and level surface that must
be able to safely withstand the weight of the
appliance loaded to maximum capacity.
The appliance must be transported to the in-
stallation location in its packaging and it must
be handled implementing all due precautions
to prevent tipping over.
The appliance must be installed at a mini-
mum distance of 100 mm from the side wall
and 50 mm from the rear wall (fig. 1).
Remove the protective film from the outer panels, detaching it slow-
ly to prevent glue residues from remaining attached to the walls.
The appliance must be installed in an area where accidental contact
with water is not possible.
It is recommended to place the appliance underneath an extraction
hood.
1.3 Electrical Connection
By removing the components showing the symbol in fig. 3,
access is gained to the appliance's live parts; this operation
must be performed by qualified personnel.
The appliance must be placed level;
to adjust height of the levelling feet
use a bubble level as reference, as
shown in fig.2.
Ensure the extraction and/or heat
disposal opening and slits are not ob-
structed in any way.
ENG
100
Fig. 1
Fig. 3
23