Voltage Outage; Warnings And Alarms - Giorik 210FE Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENG

3.2.2 Voltage Outage

The control device MELTING (where provided) is fitted with internal
memory which, in the event of very short power outage, stores the
data set until the power is restored.
In the event the outage should extend over the storage time, the
display will read "PF" upon restart (which means Power Fail): this
message may be reset by pressing key "A" for at least one second.

3.2.3 Warnings and Alarms

In the event the MELTING device (if any) should have faults, the
display reads the relevant error message:
"EO" blinking on the display and intermittent buzzer may indicate
one of the following faults:
incorrect type of probe or probe or connection fault;
temperature verified over measurable limits
Check instrument-probe connection and proper operation of the
probe (output is disabled).
"E2" blinking on the display and intermittent buzzer indicate the fol-
lowing fault:
configuration data corrupted in memory
Try power cycling the appliance (the output is disabled).
"EOC" blinking on the display and intermittent buzzer indicate the
following fault:
cold joint offset circuit defect (the output is disabled).
Call the technical support service.
30

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido