4
x
Set-up and installation
4.5.19 Connection intelligent controller
(Smart Grid - SG)
Once the function is activated by parameter [SMART GRID] = 1
(see operating manual for the control unit), depending on the sig-
nal from the energy supply company, the heat pump is switched
to Stand-by, Normal or an operating mode with higher tempera-
tures.
To do so, the potential-free contacts SG1/SG2 of the intelligent
controller must be connected to the J8 plug, connections Smart
Grid and EVU, on the RoCon BM1 circuit board (see fig. 4-43).
4.5.20 Symbols and legend keys on connection and circuit diagrams
Symbols
Safety earthing
Low external voltage earthing
Connection terminal
Plug connection
Terminal rail
2-core cabling (non-screened)
4-core cabling (non-screened)
6-core cabling (non-screened)
Tab. 4-2 Symbol explanations for connection and circuit diagrams
Installation and operating instructions
36
Explanation
As soon as the Smart Grid function is active, the HT/NT function
is deactivated automatically. Depending on the value of the pa-
rameter [Mode SG] the heat pump operated in a different manner
(see operating manual for the control unit).
Fig. 4-43 Connection Smart Grid
Symbols
External cabling (number of individual cores and
the mains voltage are partially quoted.)
Pushbutton
DIP switch
Optional component
Plug and socket connection
3-core cabling (non-screened)
5-core cabling (non-screened)
Shielded cabling (for example 3-strand)
Explanation
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN