10.2.2 Characteristic curves for pumps
P
Residual pumping height of internal heat circulation pump
R
m
Flow rate of heating system
H
Fig. 10-6 Residual pumping height of the internal heat circulation pump
Daikin Altherma EHS(X/H)...P30B and Daikin Altherma
EHS(X/H)(B)08P50B with heating support heat exchanger
P
Residual pumping height of internal heat circulation pump
R
m
Flow rate of heating system
H
Fig. 10-7 Residual pumping height of internal heat circulation pump
Daikin Altherma EHS(X/H)(B)16P50B with heating support
heat exchanger
10.3 Tightening torque
Component
Temperature sensor
Hydraulic line connections (water)
Gas line connections
(Coolant)
Liquid line connections
(Coolant)
Liquid line connections
(Coolant)
Backup-Heater
Tab. 10-4 Tightening torque
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN
Thread
Tightening
size
torque
all
max. 10 Nm
1"
25 to 30 Nm
5/8"
63 to 75 Nm
1/4"
15 to 17 Nm
3/8"
33 to 40 Nm
1.5"
max. 10 Nm
(hand-tight)
10
x
Technical data