CST/BERGER XP5 Manual De Instrucciones página 7

Ocultar thumbs Ver también para XP5:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
as steel studs) by using the magnets located on the rear and bottom side of the mount, or fixed
thanks to the strap (supplied) to wood studs, etc.
Trivet – Platform with 3 legs used for down plumb alignment jobs (such as framing and
drywall installation).
Target – This target is used for enhancing the visibility of the laser dot.
Strap – This strap is used for mounting the universal base to any object 17,80 cm or smaller in
diameter, in order to ensure the safety of the unit, if mounted on an unstable surface.
Carrying Case – The carrying case provides protection and ample storage for the unit, target,
universal mount, and manual.
CALIBRATION
This unit is factory calibrated and should never need calibration. But if it needs to be calibrated, it
must be done by a factory authorized service center.
OPERATIONS
Turn the laser ON and OFF. First time using the laser, install fresh batteries. Press the ON|OFF
button once to power the laser ON. The laser will project three (5) beams: plumb up, plumb down,
and three horizontals.
Out of Level. If the laser is tilted too much and can not self-level (>5º ), the solid Red LED indicates
that the laser is not plumb. Try to reposition the laser on a level surface.
Using the Laser to Plumb. To transfer a point from the floor to the ceiling, center the plumb down
beam over the point you wish to transfer. The laser will project a bright laser beam on the ceiling.
Mark the point as required.
Using the Laser to Level. Set the unit on a surface that is at a convenient height for marking a level
reference plane on walls or other surfaces. The laser will generate a horizontal point of reference
onto the surface.
APPLICATIONS
PLUMB (Fig. 2)
Place the unit on the floor or a fairly level surface near the wall or the object to be plumbed.
Measure from the wall being plumbed to the laser beam at two points. One point near the unit and
another point farther away. (Note: the greater the distance between the two points the greater the
possible accuracy).
If the measurements of the two points are the same, then the surface is plumb. If not, pull the wall
in or push it out until the upper and lower measurements are equal.
If you want to transfer a point from the floor to a point on the ceiling or vice-versa, mount the unit
on the universal mount.
Move the unit until the point you wish to transfer is centered on the laser dot. Mark the other point
as required.