Testing functions

7
Testing functions
Conduct the functional test as follows:
➤ Switch on the ignition and engage reverse gear.
✓ A short double beep sounds to indicate that it is working.
Be very careful when you first operate the device, and make sure you get to
know the various sequences of beeps.
Zone Description (see fig. 5, page 5)
1
MAGIC WATCH recognises obstacles
from a distance of around 1.5 m
(measured from the sensor) and signals
them with a series of slow beeps from
the speaker and by the illumination of
the green LED group.
2
From a distance of around 0.95 m
(measured from the sensor) MAGIC
WATCH switches to the green LED
group and to the medium beep
sequence.
3
At a distance of around 0.4 m (measured
from the sensor) and below, MAGIC
WATCH switches to the red LED group
and the the continuous tone. When you
reach this zone, stop the vehicle.
Otherwise you might damage the vehicle
or the obstacle.
In Zone 3 it can occur that obstacles are not detected, because
they are no longer within range of the sensors (depending on
design).
MAGIC WATCH is equipped with a diagnostic function: If the sensors are
defective, you will hear three short beeps instead of two when you engage
reverse gear.