Physical Installation; Environmental Requirements; Special Considerations For Outdoor Use - Franklin Electric SUBDRIVE UTILITY UT3P Manual Para Propietarios

Ocultar thumbs Ver también para SUBDRIVE UTILITY UT3P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PHYSICAL INSTALLATION

Environmental Requirements

PHYSICAL INSTALLATION
Environmental Requirements
Risk of damage to drive
installation, or environment.
Handle with care to prevent damage to the plastic components.
Do not mount VFD on equipment with excessive vibration.
Install in a location where temperature is within the range of product rating.
Mount VFD vertically (top up) for proper heat dissipation.
Do not mount VFD in direct sunlight or near other heat sources.
Do not install in corrosive environments.
Install at least 18" (45.7 cm) above the ground
Installation of non-approved screening may damage the drive and/or reduce output.
The drive is intended for operation in ambient temperatures from -13 °F to 122 °F (-25 °C to 50 °C). Use the
following recommendations when selecting a location to mount the drive:
The drive electronics are air-cooled. Allow at least 6 inches (15.24 cm) of
clearance around the unit for air flow.

Special Considerations for Outdoor Use

The drive is suitable for outdoor use with a NEMA 3R rating; however, the following
considerations should be made when installing the controller outdoors:
Mount the drive on a wall or back plate no smaller than the outer dimensions
of the enclosure in order to maintain the NEMA 3R rating.
The unit must be mounted vertically with the wiring end oriented downward,
and the cover must be properly secured (also applies to indoor installations).
NEMA 3R enclosures are capable of withstanding downward-directed rain
only. Protect from hose-directed or sprayed water as well as blowing rain. Fail-
ure to do so may result in drive failure.
Install away from direct sunlight or locations subject to extreme temperatures or humidity.
Use appropriate screening for the air inlet and outlet when installed in areas where insect or small ani-
mal intrusion is an issue. Refer to
Screens should be cleaned on a regular basis to ensure proper airflow.
14
,
or malfunction can occur due to improper handling,
"Accessories" on page 38
6 in min
(15.24 cm)
6 in min
(15.24 cm)
for ordering information.
6 in min
(15.24 cm)
Warm air
6 in min
(15.24 cm)
Cool air