Safety Notes
Read and observe all instructions. SAVE
THESE INSTRUCTIONS FOR FUTURE REFER-
ENCE.
Have the measuring tool repaired only through qualified
specialists using original spare parts. This ensures that
the safety of the measuring tool is maintained.
Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring tool
which may ignite the dust or fumes.
Keep the switched-on measuring tool away
from cardiac pacemakers. The magnetic
field can impair the function of cardiac pace-
makers.
Keep the switched-on measuring tool away from mag-
netic data medium and magnetically-sensitive equip-
ment. The effect of the magnetic field can lead to irreversible
data loss.
Product Description and Specifications
Intended Use
The measuring tool is intended for outdoor detecting of ferro-
magnetic objects, such as pipes, containers, manhole covers,
etc.
Technical Data
Magnetic Locator
Article number
Rod length
LCD display
Numerical indication
Operating temperature
Batteries (alkali-manganese)
Operating life time, approx.
Weight according to
EPTA-Procedure 01/2003
Protection class, display
Protection class, locator rod
2 610 A16 292 • 12.7.13
Product Features
The numbering of the product features shown refers to the illus-
tration of the measuring tool on the graphic page.
MT100/MT102
MT200/MT202
The accessories illustrated or described are not included as standard
delivery.
MT100
19-550
F 034 K82 1N0
72 cm
0...99
–20...+50 °C
6 x 1.5 V LR06 (AA) 6 x 1.5 V LR06 (AA) 6 x 1.5 V LR06 (AA) 6 x 1.5 V LR06 (AA)
100 h
1.1 kg
–
IP 57
1 Adjustment knob for sensitivity of sensor
2 Adjustment knob for volume control
3 Speaker
4 ON button
5 Power-line indicator (MT102)
6 Display
7 Numerical signal indication
8 Battery indicator
9 Analog signal indication (bar diagram)
10 OFF button
11 Erase button (MT102)
12 Screw for battery lid
13 Battery lid
3 Speaker
5 Power-line indicator (MT202)
6 Display
7 Numerical signal indication
9 Analog signal indication (bar diagram)
11 Erase button (MT202)
13 Battery lid
14 On/Off button
15 Buttons for adjustment of sensor sensitivity
16 Sensitivity indicator
17 Battery charge control indicator
18 Volume indicator
19 Buttons for volume control
MT102
19-102
F 034 K82 3N0
F 034 K82 4N1
72 cm
0...99
–20...+50 °C
–20...+50 °C
100 h
1.1 kg
–
IP 57
MT200
MT202
19-200
19-202
F 034 K82 5N0
70 cm
70 cm
0...99
–99...+99
–20...+50 °C
100 h
100 h
1.0 kg
1.0 kg
–
IP 57
IP 57
English | 9
–