PLACE | Corner Sensor
Corner sensors with pre-installed adhesive tape (for screws from optional hardware package, refer to page 12)
-
Determine placement of wall sensor:
Place corner sensor on the wall 10' (3.05m) above the floor or as close to the ceiling as possible.
Maximum placement height is 12' (3.65m).
It's best to dry fit the sensor to its proper location prior to permanently affixing the mount.
Corner sensor should be placed at least 12" (300mm) from any opening to prevent it from looking outside the room.
Be sure to allow at least 2" from the end of the sensor the ceiling to allow clearance to remove the sensor
from the mounting bracket.
-
Remove backing from adhesive strips
-
Bracket can be tricky to get into corner perfectly. The best method is to push top edge into corner first and
rotate the bracket downward into place.
-
Apply force to mounting bracket for at least 15 seconds to ensure bonding to surface. Full bonding time is 72 hours.
-
If corner is not square enough to bond to both walls at the same time, use mounting screws and attach to just one wall.
(Refer to page 12.)
-
Align the tab on the sensor to the corresponding slot on the mounting bracket ()and insert sensor into
the bracket until it locks in place.
Distance to floor ±3" (75mm)
Top down view
NOTICE
Sensor(s) SHOULD NOT be able to sense
motion outside of the room; i.e., the "cone of
vision" should not fall outside of room/doorway.
Corner sensors should always be adhered at
10' high or ceiling height (whichever is lower)
Page 8 of 41
1083528001 Rev B