8.7 Glossary
Symbol
Frequency
Mains frequency
f max
Maximum permissible mains frequency
f min
Minimum permissible mains frequency
df/dt max
Maximum permissible mains frequency variation per second
Iac
Output current, mains current
Iac max
Maximum permissible mains current
Iac mean
DC component of mains current (mains symmetry)
Iac mean max
Maximum permissible DC component of fed-in mains current
Ierr
Fault current, stray module current
Ierr max
Maximum permissible fault current (rms value) on the
DC side
Restart delay
Restart delay after a shutdown
Pac
Output
Pac max
Maximum output
Pdc
Input power, generator output
Vac
Output voltage, mains voltage
Vac 10min
Mean value of the mains voltage over the last 10 minutes
Vac 10min max Maximum permissible mean value of the mains voltage over
the last 10 minutes
Vac max
Maximum permissible mains voltage
Vac min
Minimum permissible mains voltage
Vdc
Input voltage, generator voltage
97
Meaning
8.8 Effi ciency
Output power relative to rated output [%]
Effi ciency SolarMax 2000S
η
P
P
AC
relativ
(250 VDC)
[W]
[%]
[%]
90
5
85.2
180
10
89.8
360
20
93.2
540
30
94.6
900
50
95.4
1800
100
95.2
European effi ciency
94.4
Effi ciency SolarMax 3000S
η
P
P
AC
relativ
(250 VDC)
[W]
[%]
[%]
125
5
87.0
250
10
91.5
500
20
94.2
750
30
94.9
1250
50
95.2
2500
100
94.4
European effi ciency
94.4
en
η
η
(300 VDC)
(400 VDC)
[%]
[%]
85.8
87.1
90.2
93.2
93.5
94.8
94.7
95.6
95.6
96.1
95.4
96.0
94.6
95.4
η
η
(300 VDC)
(400 VDC)
[%]
[%]
87.5
89.7
91.8
93.6
94.5
95.5
95.3
95.6
95.6
96.1
95.1
95.5
94.9
95.5
98