Place warning signs in the area around the unit.
-
Wear hearing protection PPE.
-
Install acoustic insulation.
There is a risk of hair or clothing getting entangled or trapped in the cooling fan through the canopy of the electrical motor that covers
the fan!
Precautions:
Do not wear loose fitting clothing, with long strings of other objects that could get entangled. Tie back long hair.
8
INTENDED USE
The TMD Atex 2G version of the series "K" compressors and suction pumps with a side channel are machinery for the production of
vacuum and/or overpressure and continual channelling of air or non toxic and non aggressive gases.
The TMD Atex Category 2G version of the 'Series K' compressors and suction pumps are group II equipment for use in environments
classified as Zone 1. They are designed and built in conformity with Directive ATEX 94/9/CE, in accordance with European standards
EN 1127-1, EN 13463-1, EN 13463-5.
Marking
Atex classification:
Use:
The unit has been designed also for channelling flammable gas; the parts of the machine are sealed and the aluminium components are
impregnated to guarantee their seal. The connection between the electrical motor and the blower is protected by a mechanical double
seal, oil flushed.
Likewise the accessories and control systems connected to the unit must conform to Directive 94/9/CE and be suitable for use in zone
1, the connection and suction and delivery pipes must be made of metal or antistatic material.
8.1
WORK AREA CLASSIFICATION
The indications above include category 2G both for the interior of the machine and the environment in which it is installed. Various
conditions may exist depending on the use of the blower as follows:
Use of the blower for
channelling
1
flammable gas
Use of the blower for
channelling non
2
hazardous fluids in
Atex classified
environments
Use of the blower
with suction of
3
ambient air and
operating in a
classified zone
8.2
WORKING CONDITIONS
• This user manual:
MUST be read carefully and understood well before doing anything with the unit;
MUST be followed meticulously;
ENERGOEKONOM spol. s r.o., Wolkerova 433, CZ-250 82 Úvaly, Czech Republic, Tel.: +420 281 981 055, info@energoekonom.cz, www.energoekonom.cz
Danger due to rotating parts: cooling fan of the electrical motor!
II 2G c T3
Suitable for channelling flammable gases and biogas in particular.
zones 1and 2
Equipment with internal explosive
atmosphere for operation in non classified
areas
Equipment with non explosive internal
atmosphere for operation in classified areas
Equipment with explosive internal
atmosphere, interfaced with process
atmospheres and for use in classified areas
Use which does not conform to intended use may cause serious injury and even death!
Non Atex
Atex
Atex
29 / 96
Atex
Atex
Non Atex
Atex