Positioning Of The Sensor For Installation; Motor Asset Of Lines W21, W22 And W50 - WEG Motor Scan Manual Del Usuario

Manual de instalación mecánica
Ocultar thumbs Ver también para Motor Scan:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Positioning of the Sensor for Installation

2 POSITIONING OF THE SENSOR FOR INSTALLATION
2.1 POSITIONING OF THE SENSOR - APPLICATION: WEG ELECTRIC MOTOR ASSET
OF LINES W21, W22 AND W50
As shown in
Figure 2.1 on page
6, the sensor should be installed at a maximum distance D = 20 mm from
the center of the motor and at a distance M from the top of the fin. The distance M varies according to the
motor line and frame, and it is indicated in
Table 2.1 on page
7.
D
Figure 2.1: Distances D and M to mount the sensor
In
Figure 2.2 on page
6, see the fixation of the sensor on a motor of W22 line.
Figure 2.2: Sensor mounted on the motor W22
Installation Manual | 6