USER'S MANUAL. PROMAX-26
4.2.5 GENERATOR (GTOR) operation mode
By means of this function the user defines the parameters of the signal in return
band that PROMAX-26 transmits to characterise the transmission channel. It is posble
to select the following parameters: frequency, power, modulation, symbol rate and
transmission type.
When starting up the instrument, it recovers the signal configuration of the last
working session and shows it on screen.
User can choose the frequencies and the levels required for its application.
To change the frequency of pilot signal modify its value using the navigation
buttons [7] or the alphanumeric keyboard [10]. The range of valid values is from 5 MHz
to 50 MHz.
In order to modify the level, press the
of the navigation buttons [7] or the alphanumeric keyboard [10] will be possible to
modify its value. The range of valid values is from 60 to 110 dBµV.
02/2007
Figure 32.- Settings for pilot signal.
POWER [F5] key and, later by means
Page 41