EQUIPMENT HOOK-UP
After installing the appropriate plug for the type of power supply, connect the machine to the electrical outlet.
The electrical connection (plug) must be easily accessible, also following forming machine installation.
The distance between the machine and the socket must be adequate to not cause tension in the power supply
cable. In addition, the cable must not be located beneath the machine support feet or wheel.
If the electrical power supply cable is damaged, it must be replaced by the technical assistance service
or by a qualified technician to prevent any risks.

GROUND CONNECTION

It is mandatory that the electrical system is equipped with a ground connection and differential switch
that comply with currently enforced laws.
To overcome the phenomenon producing temporary current sudden changes and in presence of speed
variator (inverter), fit on the machine, it is necessary that the electric installation is equipped with a
Class A differential switch super immunized, type "SI", guaranteeing the continuous availability of the
electric current under full security.
3
KNEADING MACHINE START-UP AND USE
COMMAND PANEL DESCRIPTION

START-UP PHASE

Connect the forming machine to the electrical mains and turn the main switch A to the position "1".
Adjust thermostats B and C of the plates to 150° C
Programme timer D to 0.6-1 seconds.
Close the protection (see figure below) to start the raise and lower cycle of the lower disk.
FORMING MACHINES 230V MONOPHASES
Legend:
A = Main switch
B = Lower plate thermostat
B.1 = Lower pilot light
C = Upper plate thermostat
C.1 = Upper pilot light
D = Timer
E = Green START buttons