Accuracy Table
(16) DC power
Voltage range *
(Input voltage range)
600.0 mV (0.0 mV to ±600.0 mV)
6.000 V (±0.540 V to ±6.000 V)
60.00 V (±5.40 V to ±60.00 V)
600.0 V (±54.0 V to ±600.0 V)
1500 V (±540 V to ±1000 V)
1500 V (±1001 V to ±1700 V)
*1: The DC power range is selected automatically based on the voltage range.
56
1
Accuracy guarantee range (Resolution)
0.000 kVA to ±0.600 kVA (0.001 kVA)
0.00 kVA to ±6.00 kVA (0.01 kVA)
0.0 kVA to ±60.0 kVA (0.1 kVA)
0 kVA to ±600 kVA (1 kVA)
0 kVA to ±1000 kVA (1 kVA)
0 kVA to ±1700 kVA (1 kVA)
Measurement accuracy
±2.0% rdg.±0.020 kVA
±2.0% rdg.±0.20 kVA
±2.0% rdg.±2.0 kVA
±2.0% rdg.±20 kVA
±2.0% rdg.±20 kVA
±4.0% rdg.±20 kVA