Gas type
Natural Methane gas
(G20)
Gas type
Liquid gas LPG
(G31)
Gas type
Liquid gas LPG
(G30-G31)
Gas type
Liquid gas LPG
(G30-G31)
Gas type
Natural Methane gas
(G20)
Liquid gas LPG
(G30-G31)
(Table 2) BURNER FEATURES
(LV - CAT. I
Nominal
Reduced
capacity
capacity [kW]
[kW]
FRY TOP BURNER 1 module
7.25 x 2
-
(Table 3) BURNER FEATURES
(IS - CAT. I
Nominal
Reduced
capacity
capacity [kW]
[kW]
FRY TOP BURNER 1 module
7.25 x 2
-
(Table 4) BURNER FEATURES
(CY, MT, HU - CAT. I
Nominal
Reduced
capacity
capacity [kW]
[kW]
FRY TOP BURNER 1 module
7.25 x 2
-
(Table 5) BURNER FEATURES
(HU - CAT. I
Nominal
Reduced
capacity
capacity [kW]
[kW]
FRY TOP BURNER 1 module
7.25 x 2
-
(Table 6) BURNER FEATURES
(PL - CAT. II
Nominal
Reduced
capacity
capacity [kW]
[kW]
FRY TOP BURNER 1 module
7.25 x 2
-
7.25 x 2
-
)
2H
Diameter of main
By-Pass
injectors
diameter
[1/100 mm]
[1/100 mm]
AL 195 x 2
)
3P
Diameter of main
By-Pass
injectors
diameter
[1/100 mm]
[1/100 mm]
140 x 2
3B/P 29mbar
Diameter of main
By-Pass
injectors
diameter
[1/100 mm]
[1/100 mm]
140 x 2
)
3B/P 50mbar
Diameter of main
By-Pass
injectors
diameter
[1/100 mm]
[1/100 mm]
120 x 2
)
2E3P
Diameter of main
By-Pass
injectors
diameter
[1/100 mm]
[1/100 mm]
AL 195 x 2
140 x 2
Pag. 31/66
Pilot injectors
[N°]
-
27 x 2
Pilot injectors
[N°]
-
14 x 2
)
Pilot injectors
[N°]
-
14 x 2
Pilot injectors
[N°]
-
14 x 2
Pilot injectors
[N°]
-
27 x 2
-
14 x 2
Air regulation
"x"
[mm]
26
Air regulation
"x"
[mm]
16
Air regulation
"x"
[mm]
16
Air regulation
"x"
[mm]
13
Air regulation
"x"
[mm]
26
16