EPCO
Fitting in a vertical or sloping position:
Warning
Uncontrolled moving loads can cause personal
injury and material damage (risk of crushing).
If a spindle nut fracture occurs inside the EPCO,
the loads will slide down.
• Check whether additional external safety
measures to protect against spindle nut frac-
ture are necessary (e.g. toothed latches or
moveable bolts). In this way you can prevent
the load from sliding down.
Installing the effective load
• Place the centre of gravity of the effective load, if possible,
centrally to the piston rod.
• When securing the effective load make sure that no torque
is transferred to the piston rod.
The wrench flat 6 can be used to exert counter pressure.
• Secure the effective load to the piston rod.
The piston rod will bend depending on the effective load
(
Appendix 13 Characteristic curves).
Size
Piston rod thread
Male thread
(EPCO-...)
Female thread
(EPCO-...-F)
Spanner Size 6
Tab. 2
Festo – EPCO-Z6 – 1207a English
16
M 6
M 4
ß
7
Fig. 3
6
Fig. 4
25
40
M8
M10x1.25
M6
M8
9
10
21