Power supply wiring
EN
Option 1: 400 V 3-phase with neutral
For 3-phase use of a Wye-connected sec-
ondary, all three phases (L1, L2 and L3) and
neutral must be connected. Each phase
voltage must measure 230 V to neutral.
Option 2: 230 V 1-phase with neutral
For 1-phase use of a Wye-connected sec-
ondary, only a single phase (L1 or L2 or L3)
and neutral on the grid must be connected
to the L1 and N on the terminal block of the
charging station. This phase voltage must
measure 230 V between line and neutral.
Note: Make sure to connect the single
phase power supply to L1 of the charging
station (not L2 or L3), as the internal elec-
tronics of the wallbox are supplied from L1.
Option 3: 230 V 1-phase without neutral
In this configuration (without neutral and
230 V from line to line), connect any two
lines (L1, L2 or L3) of the grid to L1 and N
on the terminal block of the charging sta-
tion.
Note: Make sure to connect the single
phase power supply to L1 of the charging
station (not L2 or L3), as the internal elec-
tronics of the wallbox are supplied from L1.
27