LED states
50
Wallbox
Explanation
status
Critical
Charging not possible
temperature
This error occurs when the temperature
inside the wallbox is too high.
▶ If the wallbox does not recover
▶ If this error occurs more often, make
Loss of
Charging not possible
protective
Note: The ŠKODA iV Charger detects
earth
if it is correctly connected to ground
by measuring the L1 to PE (Protective
Earth) voltage.
▶ Have voltage between L1 and PE
A – If voltage is close to 0 V, then L1 and
N might be swapped.
B – If the voltages are different for each
measurement, the ground connection is
possibly floating.
Possible solutions:
▶ For TN and TT grounding schemes
▶ In case of IT grid or 1-phase without
▶ If the error still occurs, and a safe
from the critical temperature state,
disconnect it from the car. Wait for
at least one hour for the wallbox to
cool down.
sure that the wallbox is protected
from heat sources (direct sunlight).
measured multiple times:
(not applicable to 1-phase without
neutral): Have the wallbox checked
for a proper ground connection.
neutral, have the ground monitor
functionality disabled via DIP-switch
5 of Group A.
operation of the wallbox and its
upstream installation is ensured, have
the ground monitor functionality dis-
abled via DIP-switch 5 of Group A.