DORMA
Arm installation (opposite hinge side)
10a
Connect the two components of the standard arm.
Fit spindle extension into arm. Ensure that the
11a
position of the square section insert relative to the
arm is correct.
Tap the spindle extension home using a rubber
mallet, hammer and wooden block or similar.
Place the main arm onto the drive spindle so that it is
12a
at right angles to the door frame, and secure with
washer, spring washer and cheesehead screw.
Secure the arm fixing bracket with two screws to the
13a
door leaf.
Wind or unwind the adjustment screw so that, when
14a
the arm sections are connected, the lower arm is at
right angles to the door.
Clip main arm and lower arm together.
Secure the adjustment screw with the lock nut.
Slide channel arm installation (opposite hinge side)
Marking on spindle:
10b
L = Spindle extension for left-hand
(ISO 6, CCW closing) doors
R = Spindle extension for right-hand
(ISO 5, CCW closing) doors
Fit spindle extension into arm. Ensure that the
position of the square section insert relative to the
arm is correct.
Tap the spindle extension home using a rubber
mallet, hammer and wooden block or similar.
Prepare sliding track for installation.
Close valves 3 and 4.
11b
Position arm at an angle of 45° to door frame and fit
over operator spindle and fix with cheesehead screw,
washer and spring washer.
Fit slide channel over slide shoe.
12b
Fix end caps on slide channel.
13b
Fix slide channel and adapter plate to door leaf.
(adapter plate isn´t applicable when using soundproof
version)
Open valves 3 and 4.
Slide channel arm installation (hinge side)
Marking on spindle:
10c
L = Spindle extension for left-hand
(ISO 6, CCW closing) doors
R = Spindle extension for right-hand
(ISO 5, CCW closing) doors
Fit spindle extension into arm. Ensure that the
position of the square section insert relative to the
arm is correct.
Tap the spindle extension home using a rubber
mallet, hammer and wooden block or similar.
Prepare sliding track for installation.
Close valves 3 and 4.
11c
Position arm at an angle of 45° to door frame and fit
over operator spindle with cheese head screw to
prevent it from slipping off.
Rotate arm 90° in hinge direction (preload).
Leave arm in this position.
Remove arm from spindle, refit at original position
12c
(45° to door leaf) and fix with cheesehead screw,
washer and spring washer.
Fit slide channel over slide shoe.
13c
Open valves 3 and 4.
Slide channel is automatically pushed against door
leaf.
Fix end caps on slide channel.
14c
ED 200
Fix slide channel and adapter plate to door leaf (not
15
applicable when using soundproof version)..
Set closing force using adjustment screw on side of
operator (not size EN 7).
If the ED 200 has a factory-fitted control module,
this may have to be detached.
Maximum force at main closing edge must not
exceed 150 N
1)
Forces higher than 150 N can cause injury.
16
Adjust closing speed in the range of 115
valve 3.
17
Adjust closing damping in the range of 25
valve 4.
ED 200 operator with factory-fitted control module:
In the case of double doors, link the control modules
by interconnecting cable.
Connect any auxiliary components and accessories to
the control module as appropriate.See relevant
terminal assignment and connection diagrams.
Continue from Fig. 20.
Fixing of controlboard
18
Control module A = Standard control
Control module B = Enhanced control
Fix control module plus transformer with two screws
to operator cylinder unit. Adjust wires so that cover
can be fitted without damaging them.
19A
Fit connectors to control module.
Consult individual terminal assignments/connection
19B
diagrams in performing the following operations.
Connect programme switch wires to control module.
In the case of double doors, link the control modules
by interconnecting cable.
Connect any auxiliary components and accessories to
the control module as appropriate.
20
Adjust door opening angle: Move door leaf to
required open position and adjust black cam using
pin supplied until the cam activates the microswitch.
Fix cam in this position.
Switch must be activated at an angle less
than 115° (max. door opening angle) to allow
motor pump to switch off.
21
If using control module "B" adjust mode switch
A = single door mode
B = double door mode
C = application with motor lock
22
Set both mains ON/Off switch 1 and program
switch 2 to "OFF".
Connect to mains.
Unlatch emergency button ( usually next to door).
Set mains On/Off switch 1 to "ON".
Set programme switch 2 to "Automatic".
Activate operator by means of eg. radar or
pushbutton, and check performance. Adjust settings
as necessary.
As specified in German guidelines for power-operated
1 )
1 )
1 )
1 )
1 )
windows, doors and gates
- 25
by
0
0
- 0
by
0
0
27