DORMA
Opening speed adjustable at valve 1 in the range 0
23
Delayed action adjustable at valve 2 in the range 75
24
- 115
.
0
Adjust hold open time by potentiometer in the range
25
from 0 - 30 secs.
Note: For the door to reach the open position, the
hold-open time must be adjusted to a larger value
that the total time set at valves 1 and 2. The hold-
open time starts with the activation signal.
Option IRS safety sensor on hinge-side.
26
If necessary use white cam to adjust the blanked
range of the IRS sensor (i.e. area for which sensor is
disabled). Turn the cam with the pin supplied until
the microswitch is activated. Ensure that the position
of the black cam remains unchanged.
Note: As the door opens to this point, the hinge-side
IRS sensor ceases to operate so that the door is not
tripped by obstacles in the blanked range.
Ensure that the white cam, once adjusted,
does not also activate the limit switch in the
"Door Closed" position.
Sensors in accordance with the relevant fixing
instructions.
Functional checks
Possible programme switch settings:
Programme switch integrated in ED200:
Automatic - OFF - Permanent open
External programme switch:
OFF - Exit only - Permanent open - Automatic
(only possible with control module B).
Check internal activator.
Door opens after signal emission in "Automatic" and
"Exit only" modes, and closes after hold-open time.
Check external activator.
Door opens after signal emission in "Automatic" and
"Exit only modes" and closes after hold open time.
Option: "Opening Assist"
(Control module A and B).
Once door has been slightly moved from its closed
position, operator moves leaf to fully open position
and closes door after preset hold-open time.
Option: "Night Bank" activator
(only available with control module B)
Door unlocks and opens on signal emission with
programme switch set to "OFF". After approx. 5
DORMA GmbH + Co.KG Postfach 40 09
28
ED 200
o
D-58247 Ennepetal
Tel. +49 (0) 23 33 / 793-0
o
seconds, door closes again automatically.
- 75
.
Option: IRS Sensor
0
Hinge-side:
If the IRS detects an obstacle (person) in its
detection range
- doors stops moving during the opening cycle
- door stays closed if already in closed position
Once the detection range is free, the operator is re-
enabled and continues operation in the preset mode.
Opposite hinge side:
If the IRS detects an obstacle (person) in its
detection range
- door reverses during closing cycle
- door stays open if already in open position
Once the detection range is free, the operator is
re-enabled and continues operation in the preset
mode. The IRS on the opposite hinge side is switched
off automatically by control module B after 5 sec.
and reactivated only when door starts moving again.
Option: Locking system (electric strike plate), fail
safe, fail secure
Door is locked in closed position. If operator is
activated, door will unlock and move leaf to open
position (fixed unlocking signal pulse duration of 1
sec.)
Option: Motorlock SVP 2xxx
(only available with control module B).
Door is locked in closed position. If operator is
activated, motor lock unlocks and operator opens
the door.
Completion
27
Connect earthing cable
Install cover and fix with two screws.
Fix DORMA and ED 200 labels
Pay attention to protecting the secondary
closing edge during installation
User familiarisation
After commissioning and adjustment of the operator
and accessories, the operating instructions must be
handed to the owner/user and the owner/user properly
familiarised with the system.
•
Breckerfelder Straße 42-48
•
Fax +49 (0) 23 33 / 79 34 95
D-58256 Ennepetal
• www.dorma.com