2.1.2 Electrical Installation

This equipment was developed to 110 V 60 Hz, 220 V 60 Hz or 220 V 50 Hz. When you
receive the equipment check tension printed in the tag on the electric cable.
The feeding cable has 3 pins, and the central pin is intended to the grounding. It´s
mandatory that the three points are connected before starting the appliance.
Make sure the power grid where the appliance is installed is compatible to the
tension is compatible with the tension indicated in tag in the feeding cable.

2.2 Pre-Operation

Before putting the Cabinet Discs Lid, check if the disc is well fit, avoiding damages
To start, check if the Food Processor is well positioned. Before using it, wash it with soapd
and water, the parts that are in contact with product that will be processed. (Read item
3.3 Cleaning)
2.2.1 Procedure to Discs Assembling
1 – Fit the Expelling plate N. 01 (Picture 03) in the Hub N. 02 (Picture 03);
2 – Select the desired disc(Nº 03 Fig. 03) and fit the hub N. 02 (Picture 03);
3 – Tighten the nut N. 04 (Picture 03) in Hub N 02 (Picture 03);
4 – Fit the Discs Cabinet N. 05 (Picture 03);
5 – Push the Cabinet fasteners N. 06 (Picture 03);
6 – Align the Pushing Socket N. 07 (Picture 03) in a Round Nozzle N. 08 (Picture 03);
PICTURE 02