To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Access the pilot light through the opening
2)
provided in the bottom of the appliance.
Unscrew the union (A).
3)
Remove the nozzle (B) and replace it with the
4)
one suitable for the type of gas in use (see
table at back of manual).
Retighten the union (A).
5)

EQUIPMENT DECOMMISSIONING, DEMOLITION AND DISPOSAL

When decommissioning the appliance, a seri-
GB
es of procedures must be carried out to ensure
that the appliance and its components are not a
hindrance and are not easily accessible.
To ensure that the appliance cannot constitu-
te hazards for people or the environment, all
energy sources (electricity, etc.) must be discon-
nected and rendered unusable, and any liquids
present must be drained (lubricants, fl uids, etc.).
Place the appliance in a suitable area which is
not easily accessible, with barriers to prevent an-
yone from accessing it.
3320070_inst_GB_rev.1

REPLACEMENT OF THE PILOT LIGHT INJECTOR

A
B
When scrapping, sort all components by chemi-
cal characteristics and dispose of them separa-
tely in accordance with the relevant legal requi-
rements.
Important
Do not dump non-biodegradable products,
lubricating oils, and non-metallic compo-
nents (rubber, PVC, resins, etc.) in the envi-
ronment. Dispose of them in compliance with
the relevant laws.