Important
The room where the appliance is installed
must have air inlets to ensure that the ap-
pliance can operate correctly and provide the
necessary air exchange in the room itself.
Important
The air inlets must be of appropriate size and
must be protected by gratings and placed so
that they cannot be obstructed.
Important
Those authorised to carry out this operation
must have experience acquired and certifi ed
in the specifi c sector, must make the connec-
tion to the proper standards, and must com-
ply with all the relevant regulations and legi-
slation.
Once the connection has been made, before
the appliance is put into operation a general
check must be made to ensure there are no
gas leaks.
To make the connection, connect the mains
line to the appliance's connection pipe, fi tting a
shut-off (A), to allow the gas supply to be cut off
when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible posi-
tion and its status (on or off ) must be obvious
at a glance.
3320070_inst_GB_rev.1
ROOM VENTILATION
GAS CONNECTION
Important
The gas supply pipe must comply with the
national requirements in force and must be
periodically examined and replaced if neces-
sary.
- 9 -