koban KMOS-01 Guía De Usuario página 227

Multímetro osciloscopio de verdadero valor eficaz
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

True RMS Multimeter
To save the MIN MAX screen data, the MIN MAX session must be ended by pressing the
softkey labeled Stop. Next, press the softkey labeled Save.A dialog box openswhere the
default saved name can be selected or anothername assigned. the softkey labeled Save to
store. Pressing the softkey labeled Restart while MIN MAX is running stops the MIN MAX
session, discards all MIN MAXdata, and immediately starts a new MIN MAX recording session.
5-18.Capturing Peak Value
To activate the peak mode, press the softkey
labeled Menu.Move the menu selector next
to the menu item labeledPeak, CF or Peak.
Press the softkey labeled Peak to startthe
peak recording session.
5-19.Relative Values
To activate the peak mode, press the softkey labeled Menu. Move the menu selector next to the
menu item labeled REL or Peak. Press the softkey labeled REL to start the peak recording session.
If the Meter is already in the relative function, pressing Rel% causes the Meter to turn off relative
and display relative percent.
5-20.Low Pass Filter
The Meter is equipped with an ac low pass
filter. When measuring AC voltage, press the
softkey labeled Menu to open the function
menu, and move the menu selector to the
LO item. Next, press the softkey labeled LO
to toggle the low pass filter mode.
5-21.Hold and AutoHold Mod
To freeze the display for any function, press
key HOLD.
Pressing the softkey labeled AutoHOLD
activates AutoHold if the Meter is not in the
Peak, MIN MAX, or Record modes. AutoHold
operation monitors the input signal and updates the display and, if enabled, sounds the beeper,
whenever a new stable measurement is detected. A stable measurement is one that does not
vary more than a selected adjustable percentage (AutoHold threshold) for at least one second.
The Meter filtersout open lead conditions so the Meter leads can be moved between test
points without triggering a display update.
24
s
e
1 3 : 2 5
A u t o R a n g e
-50
-40
A U T O H O L D
0 3 / 2 6 / 1 1
H o l d
0 0 0 0
50mADC
-30
-20
-10
0
10
20
30
40
S A V E
S E T U P

Publicidad

Tabla de contenido
loading

Tabla de contenido