True RMS Multimeter
5-32.Using Communications
ou can use the Wireless communication link and transfer the contents of a meter's memory
Y
to a PC.
Press the softkey labeled Setup to access the setup menu. Using the cursor buttons, move the
menu selector next to the menu item labeled communicate and press the softkey labeled PC.
press the softkey labeled open will start communications function; or press the softkey labeled
close will close communications function..
5-33.Setting Date and Time
The Meter's internal clock is used in the display and for timestamping recorded measurements.
To change the date and time as well as the display format, press the softkey labeled Setup.
Position the menu selector next to the menu item labeled Display. To set the date and time,
press the softkey labeled Date/Time to open the date/time menu. Next, position the menu
selector next to either the Set Date item or Set Time item and press the softkey labeled Edit.
Using
and
, position the cursor on the date or time element to adjust.Use
change the selected date or time element value. Press OK to complete the action.
5-34.Auto Power Off
Press the softkey labeled Setup. Position the menu selector next to the menu item labeled
Display. To set Auto Power Off and then press the softkey labeledEdit. Use
the time to one of the preset values. 0 is disable the timeout feature. Press the softkey labeled
OK to set the selected time. Press the softkey labeled Close to return.
5-35.Setting Format
Press the softkey labeled Setup. Position the menu selector next to the menu item labeled
Format. Using thecursor buttons, move the menu selector next to the menuitem labeled
Numeric(Date\Time) format, press the softkey labeled EDIT, select 0.0000(0,0000) and MM/
DD/YY(DD/MM/YY) and 24 HOUR (12 HOUR) format.
5-36.Replacing the Batteries
Refer to Figure and replace the batteries as follows:
1.Turn the Meter off and remove the test leads from the terminals.
2.Remove the battery door assembly by using a standardblade screwdriver to turn the battery
door screw one-half turn counterclockwise.
3.Replace the batteries with 7.4 volt charge batteries Observe proper polarity.
4.Reinstall the battery door assembly and secure it by turning the screw one-half turn
clockwise.