Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the stove to function correctly.
FAILURE TO PERFORM REGULAR MAINTENANCE, at least on a SEASONALbasis, could lead to poor functionality.
Any problems resulting from lack of maintenance will immediately void the warranty.

DAILY MAINTENANCE

Operations must be performed when the stove is off, cold and unplugged from the power supply
• Cleaning must be carried out with a vacuum cleaner. (see optional extras page 37).
• The whole procedure takes up a few minutes every day.
• Open the door and remove and empty the ash pan (**).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides.
• Remove the combustion chamber (1) and scrape with a spatula (supplied), clean any obstructions in the apertures.
• Suction the combustion chamber holder, clean the contact edges and remove the smoke caps (2).
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of fi re.
**
fi g. A

WEEKLY MAINTENANCE

• Cleaning the fi rebox after removing the smoke defl ector (3 - Illustr. D).
• Jiggle the brush (* - Illustr. E) located below the ceramic top.
• Empty the pellet hopper and clean the base with the vacuum cleaner.
• When cleaning the combustion chamber, lift the smoke caps (2 - fi g. F) and suction the four pipes underneath (4 - fi g. F).
N.B. To replace the smoke defl ector (3 - Illustr. D), the brush (* - Illustr. E) must be pulled up to the fully extended position.
3
fi g. D
NOTE: After every 800 kg, "Mainten." will appear to remind the user to clean the smoke channels, which is the
user's responsibility. This message will disappear by pressing the "TURBO" button for 5 seconds. Upon reaching
2000 kg of pellets, a "Mainten.-dealer" message will appear which will not disappear because the assistance
of a DEALER is required. This message can be reset from the parameters menu.