MAJOR GENERATOR FEATURES

*
5.5 HP Briggs & Stratton engine
*
Receptacles on endbell
*
Portability kit

INSTALLATION INSTRUCTIONS

Refer to the parts list and drawing on pages 5 and 6.
Tools Required: Hammer, two small adjustable wrenches or
ratchet wrench with a 7/16" socket.
WHEEL INSTALLATION
1.
Place one end of the axle (item 33) against a hard surface,
and gently tap one cap (item 29) on the other end of the
axle.
2.
Slide a wheel (item 23) onto the axle as shown in the
drawing, then slide on a spacer (item 32).
3.
Slide the axle through the two holes in the base of the
generator as shown in the drawing.
4.
On the axle end on the other side of the base (approx. 3"
long), slide on a spacer, then a wheel, as shown in the
drawing.
5.
Brace the cap on the other end to hold the axle in place,
then gently tap on the remaining cap.
FOOT INSTALLATION
1. Assemble the foot (item 19) to the carrier using a
1/4" x 1.25" bolt (item 17). Thread a 1/4" nyloc nut (item 20)
onto the bolt to secure the assembly.
Caution: Do not over tighten so that the foot material
collapses.
2. Repeat above instructions for the remaining foot.
HANDLE INSTALLATION
1.
Place the handle (item 18) onto the reduced portion of the
upright tubes of the base as shown in the diagram.
2.
Install the 1/4-20 x 1 1/4" bolts (item 17) through the tubes
from the outside.
3.
Thread the 1/4" nyloc nuts (item 20) onto the bolts and
tighten.
NOTE: Do not over tighten.
ENDBELL
A & B. 120 V, 20 Ampere Duplex Receptacle
This duplex is split so that 20 amps of current may be
drawn from each half of the receptacle. However, total power
drawn must be kept within nameplate ratings.
C. Circuit Breakers
The receptacles are protected by an AC circuit breaker. If
the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip. If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. NOTE:
Continuous tripping of the circuit breaker may cause
damage to generator or equipment. The circuit breaker may
be reset by pushing the button of the breaker.
2
LIMITED WARRANTY
(NOT VALID IN MEXICO)
This product is warranted by Coleman Powermate, Inc. to
the original retail consumer against defects in material and
workmanship for a period of one (1) year from the date of retail
purchase and is not transferable. This one year warranty
applies only to products used in consumer applications. If this
generator is used in a commercial application, then the period
of warranty coverage is limited to ninety (90) days from the date
of purchase.
Please complete and return the enclosed Customer
Information Card so that we can reach you in the unlikely event
a safety recall is needed. Return of this card is not required to
validate this warranty.
WHAT IS COVERED: Replacement parts and labor.
WHAT IS NOT COVERED: Transportation charges to
Coleman Powermate, Inc. for defective products.
Transportation charges to consumer for repaired products.
Brushes, fuses, rubber feet, and receptacles. Damages
caused by abuse, accident, improper repair, or failure to
perform normal maintenance. Power units or engines which
are covered exclusively by the warranties of their manufacturer.
Sales outside of the United States or Canada. Any other
expense including consequential damages, incidental
damages, or incidental expenses, including damage to
property. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
IMPLIED WARRANTIES: Any implied warranties, including
the Implied Warranties of Merchantability and Fitness For A
Particular Purpose, are limited in duration to one (1) year from
the date of retail purchase. Some states do not allow
limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
HOW TO OBTAIN WARRANTY PERFORMANCE:
Replacement parts and service are available from Coleman
Powermate, Inc. Service Centers. Locate your nearest Service
Center by calling TOLL FREE 1-800-445-1805. In the unlikely
event a Service Center can not be located you may call
Coleman Powermate, Inc. for a return authorization number.
Any unit returned WITHOUT an authorization number will
be refused.
To the extent any provision of this warranty is prohibited by
federal, state, or municipal law, and cannot be preempted, it
shall not be applicable. This warranty gives you specific rights,
and you may also have other rights which vary from state to
state.