Max. input current: 1000A CC
3.2.3 DC Voltage
Range
400mV
4V
40V
400V
600V
- Input impedance: 10MΩ
- Max. input voltage: 600V CC
Note:
At small voltage range, unsteady readings will appear before the test leads
contact the circuit. This is normal because the meter is highly sensitive. When
the test leads contact the circuit, the true reading will be shown.
3.2.4 AC Voltage
Range
4V
40V
400V
750V
- Input impedance: 10MΩ
- Max. input voltage: 600V CA rms
- Frequency range: 40 ~ 400Hz
KPS-PA60 • Digital clamp meter
Resolution
0,1mV
± (1,0% of reading + 2 digits)
0,001V
0,01V
± (0,7% of reading + 2 digits)
0,1V
1V
± (0,8% of reading + 2 digits)
Resolution
0,001V
0,01V
± (0,8% of reading + 3 digits)
0,1V
1V
± (1,0% of reading + 4 digits)
32
Accuracy
Accuracy