KPS-PA60 • Digital clamp meter
INPUT jack.
• Set the rotary selector to at the V range position.
• Connect the test leads to the voltage source or load terminals for measu-
rement.
• Take the reading on the LCD.The polarity symbol denotes the polarity of the
end connected by the red test lead.
NOTE:
1) At small voltage range, unsteady readings will appear before the test leads
contact the circuit. This is normal because the meter is highly sensitive. When
the test leads contact the circuit, the true reading will be shown.
2) "
"means the maximum input voltage is 600V DC.
3) If the test result is more than 600V DC, symbol "OL" will be displayed on
LCD and the build-up buzzer will sound.
4.13 Measuring frequency
4.13.1 By A range (from current clamp):
• Set the rotary selector to the A range position.
• Press the trigger to open jaw. Fully enclose only one conductor.
• Press the "Hz/%" to switch to the frequency measurement.
• Take the reading on the LCD.
NOTE:
1) Do not put more than one cable into the jaw during test, otherwise incorrect
test value might be obtained.
2) Frequency test range is 10Hz - 1kHz. „00.0‟ will be displayed on LCD if the
test frequency is lower than 10.0 Hz. It is possible to test the frequency which is
higher than 1 kHz but the tolerance of the test result can not be ensure.
3) "
" means the maximum input current is 1000A rms AC.
4.13.2 By V range:
• Plug the black test lead into the COM jack and the red test lead into the
INPUT jack.
• Set the rotary selector to the V range position .
• Press the "Hz/%" key to switch to frequency measurement.
• Connect test leads to the two ends of the source or load for measurement.
• Take the reading on the LCD.