Plumbing Recommendations (Cont.)
For optimal performance adhere to the pressure tank size recommendations shown in the
table below.
Basic Setup (DIP Switches)
For basic set-up, DIP SW1 Position 1 (FE Connect switch) must be in the "OFF" (down) position
for DIP switch, Pressure Setpoint, and Underload Potentiometer settings to be recognized.
To allow for basic setup, a new DIP switch (SW1 Position 6) has been assigned to choose
between submersible (SUB) and surface/centrifugal pumps (CEN). When CEN is selected,
the submersible MOTOR (hp) and PUMP (hp) switch banks (DIP SW2 and SW3) are
repurposed to configure surface pump parameters. These new parameters are indicated on
the shield in the white banner highlighting the CEN selection, shown in the excerpt below:
MD
50
HZ
ON
1
SD
60
HZ
DISPLAY VITRINE
ESCAPARATE
Running
STATUS
Funcionando
Funcionando
ÉTAT
En Marche
ESTADOS
30-80 Hz
See owners manual for
more information
Consulté le manuel
Drive Selection
du propriétaire pour plus
d'information
Para mayor información, lea
SubDrive Connect units used in surface pump applications can only operate 3-phase 230V
el Manual de Usuario.
motors. Ensure that DIP SW1 Position 2 is in the "OFF" (down) position, which is indicated
Tighten all other terminals to
5 in-lbs.
by "SD". Selecting "MD" when configured for a surface pump will result in an Invalid
Serrer tous les autres
terminaux à 5 po-lb.
DIP Switch Fault indicated by F24 on the display. See owner's manual for operation in
Apriete todas las demás
terminales a 5 pulgadas-libra.
submersible pump applications.
Pollution Degree 2
Degré de pollution 2
Grado de Contaminación 2
Solid State Motor Protection:
115 to 120 percent Full Load
Current
Protection de moteur à
2
semi-conducteurs: 115 à 120 pour
cent de pleine charge
Protección del motor de estado
sólido:
115 a 120% corriente a plena carga
Suitable for use on a circuit
capable of delivering not more than
5000 rms symmetrical amperes,
Maximum Pump Flow
10 GPM
20 GPM
30 GPM
40 GPM
SF
PS
CEN
XDCR
SUB
8
SW1
F1
- - -
Idle
Motor
Running
Running
Mode
Underload
Funcionando
Mode
Sous-Charge
Veille
du Moteur
En Marche
En Marche
Modo
Baja Carga
0-199 psi
0-19.9 bar
Inactivo
del Motor
Minimum Pressure Tank Size
2 Gallons
4 Gallons
6 Gallons
8 Gallons
MOTOR OVERLOAD ( A )
MOTOR SOBRECARGADO/SURCHARGE DU MOTEUR
5.9
5.6
5.3
5.0
4.7
MOTOR/MOTEUR/MOTOR (hp)
1/2
3/4
1
1.5
2
1
SW2
F2
F3
F4 F5 F6
Under
Locked
Incorrectly
Open
Voltage
Pump
Wired
Phase
Short Circuit
Sous
Pompe
Câblage
Phase
Court-Circuit
Tension
Verrouilleé
Incorrect
Ouvert
Corto Circuito
Bajo
Bomba
Cableado
Circuito
Voltaje
Bloqueada
Incorrecto
Abierto
SYSTEM RESPONSE
RESPUESTA DEL SISTEMA
SYSTÈME DE RÉPONSE
FAST MED SLOW
RÁPIDO MEDIO
LENTO
4.1
2.9
2.3
VITE
MOYEN
PUMP/POMPE/BOMBA (hp)
3
1/2
3/4
1
1.5
6
1
SW3
F7
F24
Overheated
Invalid Dip
Drive
Switch Setting
Entraînement
Réglage Invalide Du
Surchauffé
Commutateur Dip
Variador
Configuración Del
Sobrecalentado
Interruptor Dip Inválida
20
PRESSURE TRANSDUCER
CAPTEUR DE PRESSION
TRANSDUCTOR DE PRESION
226197130,6
WARNING – Retain Owner's Manual.
Installation and operation of this
equipment requires detailed
instructions as provided in the
Owner's Manual.
AVERTISSEMENT - Conserver le
manuel du propriétaire. L'installation
et le fonctionnement de cet
équipement nécessite des
instructions détaillées fournies dans le
manuel du propriétaire.
ADVERTENCIA – Conserve el Manual
MIN
Hz
15 Hz
LENT
2
3
ON
6
+
-
DEFAULT
PAR DÉFAUT
PREDETERMINADA
+
UNDERLOAD
SOUS-CHARGE
CARGA BAJA
PSI
50
40
60
30
70
80
10
90

Publicidad

Tabla de contenido
loading

Tabla de contenido