Advanced Options
• Bump Mode
• Tank Size (not used with analog pressure transducer)
• Steady Flow (not used with analog pressure transducer)*
• Broken Pipe Detection
• Wet Floor Detect Input
• Auxiliary Input
• Units (hp or kW)
• Reset to Defaults
• Available Firmware Update
* In order to modify these settings using the FE Connect mobile app, the FE Connect DIP
switch (SW1 Position 1) on the drive must be in the "ON" (up) position. Otherwise, the drive
will default to the settings made via the DIP switches, Pressure Setpoint, and Underload
Sensitivity rotary knob on the drive itself.
Mobile App Additions
Below is a summary of the parameters in the FE Connect mobile app that were added or
modified to support the new surface pump functionality. These changes require FE Connect
mobile app version 2.2.0 or later.
Drive Application
- Submersible or Surface
Motor Poles
- 2 or 4 Pole (RPM display)
Motor Overload Current
- Exact user entry
SubDrive Connect Surface Pump
Minimum Output Frequency
- Selection between 15 Hz and
(Maximum - 1) Hz
System Response
- Fast/Med/Slow/Custom
Ramp Rate
- 10 to 100%
- Small and Large Tank Reference
Prime Delay
- Selectable from 0 sec to 5 min.
New Parameter
5