Menu stage 5: opening force limit
If you previously quit the setting menu, press and
hold button
for 3 seconds until "3" is displayed.
Then press button
twice until "5" is displayed.
After approx. 2 seconds the display flashes showing
the set value of the force limit for the opening phase.
The factory setting is "6".
The force limit setting can be increased or decreased
via the
and
buttons. After selecting the setting,
press button
. "6" is displayed.
12
Menu stage 6: closing force limit
After approx. 2 seconds the display flashes showing
the set value of the force limit for the closing phase.
The force limit setting can be increased or decreased
via the
and
buttons.
After setting the value, press button
displayed.
Finally, check the force settings and, if necessary,
repeat the setting procedure.
The force at the main closing edge must not exceed
the values specified in DIN EN 12453. Depending on
how the gate is used and the need to consider
national regulations, it may be necessary to
introduce protective measures over and above this.
If the force is set too high, this can result in
injury to persons or damage to property.
The factory setting is 4, if a higher setting is
selected, proof must be furnished that the
forces are being observed.
13
Checking the force limit device
-
Position the force measuring device in the
closing area.
(If no measuring device is available, use, for
example, the operator's cardboard box).
-
Start the gate from the open position.
-
The gate travels towards the obstruction, stops
and reopens.
If alterations were made to the gate, then the force-
learning procedure must be repeated: Call up menu
stage 5 and keep the button
seconds. "0" is displayed. Then carry out force-
learning operations as explained under point
14
Menu stage 1: programming the starting
function for the hand transmitter
Briefly press button
. "1" is displayed.
As soon as the display starts to flash, keep the button
of the hand transmitter, with which you would later
like to start the operator, pressed for approx. 1
second.
As soon as the code has been read in, the red
incremental display (a) flashes five times to
acknowledge it.
Further hand transmitters (up to a max. of 10 button
codes) can be programmed.
15
Menu stage 2: programming the partial
opening function for the hand transmitter
Press button
. "2" is displayed.
Note: If no partial opening function is to be
programmed, press button
once again
"0" is displayed indicating that the programming is
completed. Press the second button on the hand
transmitter with which partial opening is to be
switched on
15a
.
As soon as the code has been read in, the red
incremental display (a) flashes five times to
acknowledge it.
After the code has been learned, briefly press button
.
15b
. "0" is displayed. End of menu.
Deleting all the hand transmitters programmed
for the operator:
Plug operator into mains whilst keeping button
pressed.
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!

Special Settings

Menu stage 7: light phases for the signal light
Keep button
displayed. Press button
stage 6 is displayed.
Keep button
"7" is displayed.
Menu
Light
value
phase
0
-
1
-
2
60 s
3
60 s
4
-
5
-
. "0" is
6
60 s
7
60 s
8
-
9
-
The setting can be altered via buttons
factory setting is "0". Press button
menu.
Menu stage 8: Soft runs
Press button
Menu
Start
value
Open
0
0
1
15
2
0
3
15
4
15
5
15
6
15
7
15
8
15
9
Menu stage 9: Special functions
pressed for 3
Press button
10.
Menu
Operating mode
0
Normal operation
(standard setting ex factory)
1
OPEN-CLOSE operation
1
operation with single-lane control
(only together with traffic light control)
External safety device
Photocell required
2
Automatic closing
External safety device
Photocell required.
Set hold-open phase in menu stage A
3
Automatic closing
Cancellation of hold-open phase by
photocell
4
Automatic closing
Cancellation of the hold-open phase by the
impulse generator
15b
.
The functions are described in the operating
instructions.
Menu stage "A": hold-open phases
Press button
only be set for the menu values 2, 3 or 4 set under
menu stage "9".
Menu
Hold-open phase
value
(plus 10s flashing as advance warning)
0
0 s
1
10 s
2
30 s
3
60 s
4
90 s
pressed for 3 seconds. "3" is
repeatedly until menu
pressed for another 3 seconds until
Advance warning Flashing
phase
function
-
yes
-
-
-
yes
-
-
3 s
yes
3 s
-
3 s
yes
3 s
-
10 s
yes
10 s
-
and . The
to end the
. "8" is displayed.
Stop
Start
Stop
Open Close
Close
0
0
0
0
15
0
15
0
60
25
15
60
15
15
60
60
15
60
15
15
15
25
15
85
60
15
85
only soft run
. "9" is displayed.
or
. "A " is displayed. These phases can
5
120 s
6
150 s
7
180 s
8
210 s
9
240 s
16
Safe operation of the gate system
Before initial operation, test the function and safety
of the operator.
All the requirements regarding the safe operation of
the system must be met.
In the case of systems accessed by the public or
used in the automatic closing mode, a photocell must
be installed.
It is recommended that a warning light be installed.
Main closing edge 16a
IIn the closing phase the force when distance
X is less than 500mm may not exceed 400N;
X is greater than 500mm may not exceed
1400N.
This is achieved by using safety profiles:
Gate weight
Manufacturer
up to 400kg
tormatic
up to 400kg
tormatic
up to 400kg
ASO
up to 400kg
Gelbau
up to 400kg
Mayser
up to 200kg
ASO
up to 200kg
Bircher
up to 200kg
Gelbau
Further insertable profiles can be obtained from the
manufacturer on request.
Because of the force limit device integrated into the
operator, the main closing edge may only be
equipped with a passive rubber profile (without
evaluation function).
Rear closing edge 16b
The safety distances are adhered to if:
x is greater than 500mm or
y is less than100mm and X greater than 200mm
If the safety distances cannot be adhered to, then
this area can be safeguarded either by using a
protective fence or by applying a force limit.
In the case of a force limit, the rear closing edge must
be safeguarded by a safety profile as is the case with
the main closing edge.
Additionally, the distance of the STOP-OPEN soft
run must be correspondingly extended. (Menu 8
value 3 or 5).
Main closing edges 16c
If secondary closing edges form, these must be
equipped with safety profiles
gate weight manufacturer type
up to 300kg tormatic
35 / 50
up to 400kg tormatic
35 / 70
Other profiles used a resistor for terminating voltage
of 8k2.
Protective fence 16d
If access to the gate is safeguarded by fencing, the
maximum opening width A has to be adjusted to
distance X.
Distance
Opening size A
X l 120mm
less than 18,5mm
X less than 300mm
less than 29mm
X less than 500mm
less than 44mm
X less than 850mm
less than18,5mm.