6 Commissioning
1
Wire guide
Fig. 16
Feeding in the wire
3 Thread the wire into the feeder side, manually or with the assistance of the rear wire feeder.
Ensure that the wire is fed correctly through the wire guides (1) on the MF3-Laser Front/Rear.
4 Swivel-in the rocker arm.
1
1
Inching forward
Fig. 17
Trigger
Trigger
Inching forward (1) (press once)
Inching forward (1) (press twice)
Gas test (2)
Trigger (3)
Tab. 13
Trigger assignment
EN - 18
1
2
Wire
2
2
Gas test
Function
Wire is fed forward (with an increasing speed from 0 to
10 m/min)
Wire is fed backward
Opens the gas valve
No function
MF3-Laser Front/Rear
2
3
3
Trigger with no function
BAL.0511.0 • 2019-06-13