Warning
Faults in parametrizing can cause injury to human
beings and damage to property if the controller is
enabled with a 1−signal at the ENABLE input.
Enable the controller only if the axis system is correctly
installed and parametrized.
1.2 Notes on the movement test
Warning
The controller is switched off during the movement test.
This is to prevent the pneumatic axes from making
sudden uncontrolled movements when the supply pres
sure is switched on. The set software end positions
have no effect.
If you wish to carry out the movement test with the sup
ply pressure switched on:
S Make sure that the complete positioning range of the
pneumatic axes is free.
S Point out the danger to other people by means of
suitable warning signs or protective screens.
S Keep the acceleration forces at a low level. To do this
set a low supply pressure of maximum 3 bar and
remove the work load and the tool load.
Note the following instructions on carrying out the move
ment test with the different SPC200 operating system
versions and WinPISA versions.
Festo SPC200−... 0504c English
15