Carrying out the movement test with the different SPC200
operating system versions and WinPISA versions
As from
operating
system V4.6
with
WinPISA 4.3
As from
operating
system V4.6
with
WinPISA 4.1x
or earlier
Operating
system V3.80
with
WinPISA 4.3,
WinPISA 4.1x
or earlier
16
1. Before the movement test: 0−signal at ENABLE
2. Access the movement test for the desired axis
(see system manual or WinPISA manual).
3. Apply a 1−signal at ENABLE.
4. Carry out the movement test: Modify the valve
voltage and check the direction of movement.
A 0−signal at ENABLE will set the valve voltage to 5 V
and interr. the movement test (with fault message).
5. In order to conclude the movement test, apply a
0−signal at ENABLE.
Note the newly defined signal behaviour of the SPC200
during the movement test.
1. Before the movement test: 0−signal at ENABLE
2. Access the movement test (see WinPISA manual).
3. Select the axis.
4. Apply a 1−signal at ENABLE.
5. Carry out the movement test for the selected axis:
Modify the valve voltage and check the direction of
movement.
6. Apply a 0−signal at ENABLE.
7. Select another axis and repeat steps 3 to 6 or close
the dialogue window Movement test."
S Before accessing the movement test, apply a
1−signal at ENABLE, START and STOP.
With WinPISA 4.3: Differing from the messages
displayed, a 1−signal is always required at ENABLE.